Literature DB >> 18693508

Improved detection of the central reflex in retinal vessels using a generalized dual-gaussian model and robust hypothesis testing.

Harihar Narasimha-Iyer1, Vijay Mahadevan, James M Beach, Badrinath Roysam.   

Abstract

This updates an earlier publication by the authors describing a robust framework for detecting vasculature in noisy retinal fundus images. We improved the handling of the "central reflex" phenomenon in which a vessel has a "hollow" appearance. This is particularly pronounced in dual-wavelength images acquired at 570 and 600 nm for retinal oximetry. It is prominent in the 600 nm images that are sensitive to the blood oxygen content. Improved segmentation of these vessels is needed to improve oximetry. We show that the use of a generalized dual-Gaussian model for the vessel intensity profile instead of the Gaussian yields a significant improvement. Our method can account for variations in the strength of the central reflex, the relative contrast, width, orientation, scale, and imaging noise. It also enables the classification of regular and central reflex vessels. The proposed method yielded a sensitivity of 72% compared to 38% by the algorithm of Can et al., and 60% by the robust detection based on a single-Gaussian model. The specificity for the methods were 95%, 97%, and 98%, respectively.

Entities:  

Mesh:

Year:  2008        PMID: 18693508     DOI: 10.1109/titb.2007.897782

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  6 in total

1.  Recent Advancements in Retinal Vessel Segmentation.

Authors:  Chetan L Srinidhi; P Aparna; Jeny Rajan
Journal:  J Med Syst       Date:  2017-03-11       Impact factor: 4.460

2.  Automatic labeling of portal and hepatic veins from MR images prior to liver transplantation.

Authors:  Evgin Goceri
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-06-23       Impact factor: 2.924

3.  Non-mydriatic chorioretinal imaging in a transmission geometry and application to retinal oximetry.

Authors:  Timothy D Weber; Jerome Mertz
Journal:  Biomed Opt Express       Date:  2018-07-25       Impact factor: 3.732

4.  Fast retinal vessel detection and measurement using wavelets and edge location refinement.

Authors:  Peter Bankhead; C Norman Scholfield; J Graham McGeown; Tim M Curtis
Journal:  PLoS One       Date:  2012-03-12       Impact factor: 3.240

5.  Retinal vessel segmentation: an efficient graph cut approach with retinex and local phase.

Authors:  Yitian Zhao; Yonghuai Liu; Xiangqian Wu; Simon P Harding; Yalin Zheng
Journal:  PLoS One       Date:  2015-04-01       Impact factor: 3.240

Review 6.  Advances in Retinal Oximetry.

Authors:  Anupam K Garg; Darren Knight; Leonardo Lando; Daniel L Chao
Journal:  Transl Vis Sci Technol       Date:  2021-02-05       Impact factor: 3.283

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.