Literature DB >> 18693114

The thermoluminescence response of doped SiO2 optical fibres subjected to alpha-particle irradiation.

Ahmad Termizi Ramli1, D A Bradley, Suhairul Hashim, Husin Wagiran.   

Abstract

Ion beams are used in radiotherapy to deliver a more precise dose to the target volume while minimizing dose to the surrounding healthy tissue. For optimum dose monitoring in ion-beam therapy, it is essential to be able to measure the delivered dose with a sensitivity, spatial resolution and dynamic range that is sufficient to meet the demands of the various therapy situations. Optical fibres have been demonstrated by this group to show promising thermoluminescence properties with respect to photon, electron and proton irradiation. In particular, and also given the flexibility and small size of optical fibre cores, for example 125.0+/-0.1 microm for the Al- and Ge-doped fibres used in this study, these fibres have the potential to fulfill the above requirements. This study investigates the thermoluminescence dosimetric characteristics of variously doped SiO(2) optical fibres irradiated with alpha particles from (241)Am. Following subtraction of the gamma contribution from the above source, the thermoluminescence characteristics of variously doped SiO(2) optical fibres have been compared with that of TLD-100 rods. The irradiations were performed in a bell jar. Of related potential significance is the effective atomic number, Z(eff) of the fibre, modifying measured dose from that deposited in tissues; in the present work, a scanning electron microscope and associated energy dispersive X-ray spectroscopy facility have been used to provide evaluation of Z(eff). For Ge-doped fibres, the effective atomic numbers value was 11.4, the equivalent value for Al-doped fibres was 12.3. This paper further presents results on dose response and the glow curves obtained. The results obtained indicate there to be good potential for use of variously doped SiO(2) optical fibres in measuring ion-beam doses in radiotherapeutic applications.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18693114     DOI: 10.1016/j.apradiso.2008.06.034

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  4 in total

Review 1.  A review of recent advances in optical fibre sensors for in vivo dosimetry during radiotherapy.

Authors:  S O'Keeffe; D McCarthy; P Woulfe; M W D Grattan; A R Hounsell; D Sporea; L Mihai; I Vata; G Leen; E Lewis
Journal:  Br J Radiol       Date:  2015-03-11       Impact factor: 3.039

Review 2.  Optical fibre sensors: their role in in vivo dosimetry for prostate cancer radiotherapy.

Authors:  P Woulfe; F J Sullivan; S O'Keeffe
Journal:  Cancer Nanotechnol       Date:  2016-10-18

Review 3.  Radiation Effects on Long Period Fiber Gratings: A Review.

Authors:  Flavio Esposito; Anubhav Srivastava; Stefania Campopiano; Agostino Iadicicco
Journal:  Sensors (Basel)       Date:  2020-05-11       Impact factor: 3.576

Review 4.  Recent Advances in Optical Fiber Enabled Radiation Sensors.

Authors:  Jing Zhang; Yudiao Xiang; Chen Wang; Yunkang Chen; Swee Chuan Tjin; Lei Wei
Journal:  Sensors (Basel)       Date:  2022-02-01       Impact factor: 3.576