Literature DB >> 18692662

Less invasive quick replacement for octogenarians with type A acute aortic dissection.

Mitsumasa Hata1, Mitsunori Suzuki, Akira Sezai, Tetsuya Niino, Satoshi Unosawa, Nobuyuki Furukawa, Kazutomo Minami.   

Abstract

OBJECTIVE: We assessed the efficacy of our newly modified technique, namely, less invasive quick replacement with rapid rewarming, for octogenarians undergoing emergency surgery for type A acute aortic dissection.
METHODS: Forty-two patients with acute aortic dissection, whose average age was 81.7 +/- 2.3 years, were divided into two groups: group I consisted of 25 patients undergoing surgery with deep hypothermic circulatory arrest and selective cerebral perfusion; group II consisted of 17 recent patients who underwent less invasive quick replacement. In the latter technique, during open distal anastomosis with a rectal temperature of 28 degrees C without any cerebral perfusion, circulating blood in the cardiopulmonary bypass circuit was warmed to 40 degrees C accompanied by warming of the patient's body by a heating mat. As soon as the distal anastomosis was completed, rapid rewarming was initiated by 40 degrees C blood perfusion.
RESULTS: The durations of cerebral protection (group I, 75.8 minutes, vs group II, 18.8 minutes), cardiopulmonary bypass (I, 201.2, vs II, 84.4 minutes), and overall operation (I, 425.6, vs II, 148.6 minutes) were significantly shorter in group II. In group I, 5 patients had complications of cerebral damage and 5 required re-exploration for bleeding, 7 had pneumonia, 6 required hemodialysis for renal failure, and the hospital mortality rate was 24% (6 patients). On the other hand, no such complications or mortality were observed in group II (P < .0291). Postoperative hospital stay was significantly shorter for the patients in group II than in group I (13.2 days vs 33.7 days; P < .0001).
CONCLUSION: Less invasive quick replacement is safe and effective. It should be a standard surgical technique for octogenarians with type A acute aortic dissection.

Entities:  

Mesh:

Year:  2008        PMID: 18692662     DOI: 10.1016/j.jtcvs.2008.01.007

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  Acute type a aortic dissection: for further improvement of outcomes.

Authors:  Kazumasa Orihashi
Journal:  Ann Vasc Dis       Date:  2012

2.  Efficacy of modified less invasive quick replacement using mild hypothermic arrest and partial retrograde cerebral perfusion for type A acute aortic dissection.

Authors:  Mitsumasa Hata; Yukihiko Orime; Shinji Wakui; Tomofumi Umeda; Kenji Akiyama; Masashi Tanaka
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-10-27

3.  Too Cold to Clot? Does Intraoperative Hypothermia Contribute to Bleeding After Aortic Surgery?

Authors:  Louis H Stein; Gregory Rubinfeld; Leora B Balsam; Patricia Ursomanno; Abe DeAnda
Journal:  Aorta (Stamford)       Date:  2017-08-01

Review 4.  Outcomes of surgery for acute type A dissection in octogenarians versus non-octogenarians: a systematic review and meta analysis.

Authors:  Aditya Eranki; Michael Merakis; Michael L Williams; Campbell D Flynn; Claudia Villanueva; Ashley Wilson-Smith; Yangsin Lee; Ross Mejia
Journal:  J Cardiothorac Surg       Date:  2022-09-01       Impact factor: 1.522

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.