[Slit drainage versus Redon drainage in a clinical comparison--initial experiences with a new kind of wound drainage system].

P Brandner1, K J Neis, A Hettenbach, W Schmidt.   

Abstract

In a prospective, randomised study we compared the clinical properties of the established Redon drain with a new type of drain called "slit drain". Both types of drains were examined regarding the amount of drained fluid, the time elapsing until removal of the drain, the frequency of occlusion of the lumen as well as the patient's pain and the required force at extraction of the drain. The statistical analysis showed both drains to have equal abilities in draining of fluid if they were used under vacuum conditions. If used as nonsuction drains, the new device was able to drain more fluid than the established type of drain (p less than 0.05). Statistically relevant advantages of the slit drain were seen in a lower rate of obstruction of the lumen, a higher amount of drained fluid (as non-suction device) as well as an easier and less painful extraction.

Entities:  

Mesh:

Year:  1991        PMID: 1869010     DOI: 10.1055/s-2007-1026165

Source DB:  PubMed          Journal:  Geburtshilfe Frauenheilkd        ISSN: 0016-5751            Impact factor:   2.915


  1 in total

1.  [The value of wound drainage with or without suction].

Authors:  J Schmidt; A Hasselbach; W Schnorr; T Baranek; R Letsch
Journal:  Unfallchirurg       Date:  2005-11       Impact factor: 1.000

  1 in total