Literature DB >> 18686479

Mechanical agitation and serial dilution: an option for anterior cruciate ligament graft sterilization.

Richard D Parker1, Steven D Maschke.   

Abstract

Contamination of tissue grafts can occur during anterior cruciate ligament reconstruction, necessitating decontamination. This study examined whether mechanical agitation and serial dilution provides greater bacterial eradication of experimentally contaminated bone-patellar tendon-bone grafts compared with antibiotic soak or pulsatile lavage. Forty bone-patellar tendon-bone grafts were contaminated with a bacterial suspension derived from operating room floor cultures. Four groups of specimens underwent immediate culture (control), antibiotic soak, pulsatile lavage, or mechanical agitation and serial dilution. The number of colony-forming units (CFU) for each group was statistically compared using t and chi-square tests. Each method of decontamination yielded a statistically significant reduction in CFU compared with the control. Analysis of positive versus negative cultures demonstrated a statistically significant difference between mechanical agitation and serial dilution compared with the other 2 methods. Mechanical agitation and serial dilution was the only method with 0 CFU and provided superior and consistent sterilization of experimentally contaminated grafts compared with antibiotic soak and pulsatile lavage.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18686479     DOI: 10.1055/s-0030-1247817

Source DB:  PubMed          Journal:  J Knee Surg        ISSN: 1538-8506            Impact factor:   2.757


  6 in total

1.  Evaluation of sterilization methods following contamination of hamstring autograft during anterior cruciate ligament reconstruction.

Authors:  Matthew J Plante; Xinning Li; Gail Scully; Michael A Brown; Brian D Busconi; Nicola A DeAngelis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-05-15       Impact factor: 4.342

2.  Are Dropped Bone Grafts Safe to be Re-used? - An Experimental Study Comparing Efficacy of Chlorhexidine, Povidone-Iodine and Alcohol.

Authors:  M F Mat-Salleh; A N Sadagatullah; M Y Ibrahim; I Abdul-Aziz; W A Wan-Abdullah; N Maning; M N Md-Hassan; M R Ab-Rashid
Journal:  Malays Orthop J       Date:  2021-07

3.  Hamstring autografts are associated with a high rate of contamination in anterior cruciate ligament reconstruction.

Authors:  Abdulaziz Z Alomar; Saud M Alfayez; Ali M Somily
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-29       Impact factor: 4.342

Review 4.  Comparison of the Sterilization Efficiency of 3 Disinfectants for Dropped Anterior Cruciate Ligament Grafts: A Systematic Review and Meta-analysis.

Authors:  Xianyue Shen; Yanguo Qin; Jianlin Zuo; Tong Liu; Jianlin Xiao
Journal:  Orthop J Sports Med       Date:  2021-05-10

5.  The Practices and Attitudes of Saudi Plastic Surgeons in Managing Contaminated Autologous Grafts.

Authors:  Fahad Aljindan; Fahad Alhumaid; Noor H Allababidi; Hatan Mortada; Salman Alzaidi
Journal:  Plast Reconstr Surg Glob Open       Date:  2022-08-24

Review 6.  Disinfection of human musculoskeletal allografts in tissue banking: a systematic review.

Authors:  J Mohr; M Germain; M Winters; S Fraser; A Duong; A Garibaldi; N Simunovic; D Alsop; D Dao; R Bessemer; O R Ayeni
Journal:  Cell Tissue Bank       Date:  2016-09-24       Impact factor: 1.522

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.