Determination of blood leukocyte concentration with constant volume acquisition on a flow cytometer is comparable to individualized single platform testing with beads as internal reference standard.

Susan Hansen1, Ronald Dahl, Hans Jürgen Hoffmann.   

Abstract

Flow cytometers have a constant flow rate. This enables flow cytometers to measure leukocyte concentrations in a determined volume by acquiring data at a fixed rate over a fixed time and is called constant volume acquisition (CVA). The volume aspirated by a FACS Calibur flow cytometer in 4 min at a high rate has a median of 163 microl (IQR 156-170) with TruCount tubes. Leukocyte concentrations of 26 healthy volunteers were measured twice on up to four occasions with a Bürker-Türk chamber, by single platform technology (SPT) with TruCount tubes and on the same data set using CVA. Total leukocyte concentrations determined by CVA correlated better with measurements in a Bürker-Türk (BT) chamber than with SPT. Concentrations determined with CVA were 1.86% higher than with BT whereas SPT data were 5.35% higher than BT (p<0.001), and 3.36% higher than CVA (p<0.001). At leukocyte concentrations <6 million/ml SPT correlated better with BT than CVA. The SPT measurement may be more variable because it depends on measurement of the number of beads aliquoted, the number of beads and leukocytes aspirated, where both BT counting and CVA measurements only depend on the number of leukocytes counted. CVA with PanLeukoGating can be established using microscopy as a reference, and is comparable to BT chamber and SPT determination. Leukocyte concentrations can be measured with CVA on flow cytometers in research and clinical settings.

Mesh:

Year:  2008        PMID: 18680746     DOI: 10.1016/j.jim.2008.07.010

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  3 in total

1.  Metal-Containing Polystyrene Beads as Standards for Mass Cytometry.

Authors:  Ahmed I Abdelrahman; Olga Ornatsky; Dmitry Bandura; Vladimir Baranov; Robert Kinach; Sheng Dai; Stuart C Thickett; Scott Tanner; Mitchell A Winnik
Journal:  J Anal At Spectrom       Date:  2010       Impact factor: 4.023

2.  Basophil sensitivity through CD63 or CD203c is a functional measure for specific immunotherapy.

Authors:  Susan Mikkelsen; Bo Martin Bibby; Mette Konow Bøgebjerg Dolberg; Ronald Dahl; Hans Jürgen Hoffmann
Journal:  Clin Mol Allergy       Date:  2010-02-16

3.  Activation Markers CD63 and CD203c Are Upregulated in Chronic Urticaria.

Authors:  Claus Uhrenholt Christensen; Christian Vestergaard; Hans Jürgen Hoffmann
Journal:  Ann Dermatol       Date:  2013-11-30       Impact factor: 1.444

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.