Literature DB >> 18678533

Performance of vertebral cancellous bone augmented with compliant PMMA under dynamic loads.

Andreas Boger1, Marc Bohner, Paul Heini, Karsten Schwieger, Erich Schneider.   

Abstract

Increased fracture risk has been reported for the adjacent vertebral bodies after vertebroplasty. This increase has been partly attributed to the high Young's modulus of commonly used polymethylmethacrylate (PMMA). Therefore, a compliant bone cement of PMMA with a bulk modulus closer to the apparent modulus of cancellous bone has been produced. This compliant bone cement was achieved by introducing pores in the cement. Due to the reduced failure strength of that porous PMMA cement, cancellous bone augmented with such cement could deteriorate under dynamic loading. The aim of the present study was to assess the potential of acute failure, particle generation and mechanical properties of cancellous bone augmented with this compliant cement in comparison to regular cement. For this purpose, vertebral biopsies were augmented with porous- and regular PMMA bone cement, submitted to dynamic tests and compression to failure. Changes in Young's modulus and height due to dynamic loading were determined. Afterwards, yield strength and Young's modulus were determined by compressive tests to failure and compared to the individual composite materials. No failure occurred and no particle generation could be observed during dynamical testing for both groups. Height loss was significantly higher for the porous cement composite (0.53+/-0.21%) in comparison to the biopsies augmented with regular cement (0.16+/-0.1%). Young's modulus of biopsies augmented with porous PMMA was comparable to cancellous bone or porous cement alone (200-700 MPa). The yield strength of those biopsies (21.1+/-4.1 MPa) was around two times higher than for porous cement alone (11.6+/-3.3 MPa).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18678533     DOI: 10.1016/j.actbio.2008.06.019

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  3 in total

1.  The effect of standard and low-modulus cement augmentation on the stiffness, strength, and endplate pressure distribution in vertebroplasty.

Authors:  Michael Kinzl; Lorin M Benneker; Andreas Boger; Philippe K Zysset; Dieter H Pahr
Journal:  Eur Spine J       Date:  2011-12-15       Impact factor: 3.134

2.  Direct and interactive effects of three variables on properties of PMMA bone cement for vertebral body augmentation.

Authors:  Alejandro López; Erik Unosson; Håkan Engqvist; Cecilia Persson
Journal:  J Mater Sci Mater Med       Date:  2011-04-28       Impact factor: 3.896

3.  Modification of PMMA vertebroplasty cement for reduced stiffness by addition of normal saline: a material properties evaluation.

Authors:  Christian Schröder; Mai Nguyen; Michael Kraxenberger; Yan Chevalier; Carolin Melcher; Bernd Wegener; Christof Birkenmaier
Journal:  Eur Spine J       Date:  2016-12-09       Impact factor: 3.134

  3 in total