Literature DB >> 18677509

Use of the harmonic scalpel versus conventional haemostatic techniques in patients with Grave disease undergoing total thyroidectomy: a prospective randomised controlled trial.

P Hallgrimsson1, L Lovén, J Westerdahl, Anders Bergenfelz.   

Abstract

INTRODUCTION: Thyrotoxicosis is often considered to be the most difficult thyroid operation because of the high vascularisation and the risk of bleeding. The conventional haemostatic technique in thyroidectomy today include knot tying and electrocoagulation. The introduction of the harmonic scalpel (HS) has led to further research if the use of the HS has any benefits in thyroid surgery. To our knowledge, no previous study has evaluated the HS dissection technique in a homogenous group of patients with Graves' disease undergoing total thyroidectomy.
MATERIALS AND METHODS: Fifty-one patients (39 women and 12 men) with the pre-operative diagnosis of Graves' disease treated at two endocrine centers were randomised to total thyroidectomy with the use of the HS or with conventional haemostatic techniques.
RESULTS: Twenty-seven patients were randomised to the harmonic group and 24 to the conventional group. The operating time was shorter in the HS group (median, 121 min; range, 84-213 min) compared to the conventional group (median, 172 min; range, 66-268 min; p = 0.011).
CONCLUSION: The use of the HS was associated with a significant reduction in operating time compared to the use of the conventional haemostatic techniques in patients with Graves' disease undergoing total thyroidectomy.

Entities:  

Mesh:

Year:  2008        PMID: 18677509     DOI: 10.1007/s00423-008-0361-z

Source DB:  PubMed          Journal:  Langenbecks Arch Surg        ISSN: 1435-2443            Impact factor:   3.445


  21 in total

1.  Ultrasonically activated shears in thyroidectomies: a randomized trial.

Authors:  P E Voutilainen; C H Haglund
Journal:  Ann Surg       Date:  2000-03       Impact factor: 12.969

2.  Thyroidectomy using the harmonic scalpel: analysis of 105 consecutive cases.

Authors:  Larry Shemen
Journal:  Otolaryngol Head Neck Surg       Date:  2002-10       Impact factor: 3.497

3.  [Ultrasonic scalpel in thyroid surgery].

Authors:  Maurizio Marchesi; Marco Biffoni; Riccardo Cresti; Maria Maddalena Mulas; Valeria Turriziani; Alberto Berni; Francesco Paolo Campana
Journal:  Chir Ital       Date:  2003 Mar-Apr

4.  Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model.

Authors:  Jaime Landman; Kurt Kerbl; Jamil Rehman; Cassio Andreoni; Peter A Humphrey; William Collyer; Ephrem Olweny; Chandru Sundaram; Ralph V Clayman
Journal:  J Urol       Date:  2003-02       Impact factor: 7.450

5.  Total thyroidectomy: the evolution of surgical technique.

Authors:  Leigh Delbridge
Journal:  ANZ J Surg       Date:  2003-09       Impact factor: 1.872

6.  Recurrent laryngeal nerve identification and assessment during thyroid surgery: laryngeal palpation.

Authors:  Gregory W Randolph; James B Kobler; Jamie Wilkins
Journal:  World J Surg       Date:  2004-08-03       Impact factor: 3.352

7.  Laryngeal recurrent nerve injury in surgery for benign thyroid diseases: effect of nerve dissection and impact of individual surgeon in more than 27,000 nerves at risk.

Authors:  Michael Hermann; Gunter Alk; Rudolf Roka; Karl Glaser; Michael Freissmuth
Journal:  Ann Surg       Date:  2002-02       Impact factor: 12.969

8.  The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery.

Authors:  Allan E Siperstein; Eren Berber; Ebru Morkoyun
Journal:  Arch Surg       Date:  2002-02

9.  Comparison of ultrasonically activated scalpel versus conventional division for the pancreas in distal pancreatectomy.

Authors:  H Sugo; Y Mikami; F Matsumoto; H Tsumura; Y Watanabe; S Futagawa
Journal:  J Hepatobiliary Pancreat Surg       Date:  2001

10.  The recurrent laryngeal nerve related to thyroid surgery.

Authors:  G Sturniolo; C D'Alia; A Tonante; E Gagliano; F Taranto; M G Lo Schiavo
Journal:  Am J Surg       Date:  1999-06       Impact factor: 2.565

View more
  18 in total

1.  Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments.

Authors:  Gianlorenzo Dionigi
Journal:  Langenbecks Arch Surg       Date:  2008-12-24       Impact factor: 3.445

Review 2.  ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery--the ENERCON systematic review and network meta-analysis.

Authors:  Pietro Contin; Käthe Gooßen; Kathrin Grummich; Katrin Jensen; Hubertus Schmitz-Winnenthal; Markus W Büchler; Markus K Diener
Journal:  Langenbecks Arch Surg       Date:  2013-11-16       Impact factor: 3.445

3.  Harmonic Focus™ versus "knot tying" during total thyroidectomy: a randomized trial.

Authors:  Paolo Gentileschi; Stefano D'Ugo; Edoardo Iaculli; Achille Lucio Gaspari
Journal:  Updates Surg       Date:  2011-07-26

4.  Horner's syndrome subsequent to minimally invasive video-assisted thyroidectomy in two patients.

Authors:  Kexin Meng; Wei Tian; Zhenye Lv; Xiangyang Song
Journal:  Oncol Lett       Date:  2015-04-28       Impact factor: 2.967

Review 5.  A comparison of surgical outcomes and complications between hemostatic devices for thyroid surgery: a network meta-analysis.

Authors:  Yingwei Luo; Xi Li; Jianwei Dong; Weifeng Sun
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-08-01       Impact factor: 2.503

6.  Steam induced by the activation of energy devices under a wet condition may cause thermal injury.

Authors:  Masaru Hayami; Masayuki Watanabe; Shinji Mine; Yu Imamura; Akihiko Okamura; Masami Yuda; Kotaro Yamashita; Yoshiaki Shoji; Tasuku Toihata; Ryotaro Kozuki; Naoki Ishizuka
Journal:  Surg Endosc       Date:  2019-12-06       Impact factor: 4.584

7.  Harmonic scalpel compared to conventional hemostasis in thyroid surgery.

Authors:  Oktay Yener; Mustafa Demir; Ahmet Yılmaz; Rafet Yıgıtbaşı; Tuba Atak
Journal:  Indian J Surg       Date:  2012-06-20       Impact factor: 0.656

8.  Update on sutureless thyroidectomy.

Authors:  R Ruggiero; G Docimo; A Bosco; M Lanza Volpe; G Terracciano; A Gubitosi; L Docimo
Journal:  G Chir       Date:  2018 Jan-Feb

9.  Health technology assessment and thyroid surgery.

Authors:  R Lucchini; A Sanguinetti; M Monacelli; R Triola; S Avenia; C Conti; S Santoprete; N Avenia
Journal:  G Chir       Date:  2013 Jul-Aug

10.  The comparison of the harmonic focus shears device with conventional clamp binding in total thyroidectomy.

Authors:  Fatih Çiftçi
Journal:  Int J Clin Exp Med       Date:  2015-10-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.