Literature DB >> 18676147

Foot contact event detection using kinematic data in cerebral palsy children and normal adults gait.

Eric Desailly1, Yepremian Daniel, Philippe Sardain, Patrick Lacouture.   

Abstract

Initial contact (IC) and toe off (TO) times are essential measurements in the analysis of temporal gait parameters, especially in cerebral palsy (CP) gait analysis. A new gait event detection algorithm, called the high pass algorithm (HPA) has been developed and is discussed in this paper. Kinematics of markers on the heel and metatarsal are used. Their forward components are high pass filtered, to amplify the contact discontinuities, thus the local extrema of the processed signal correspond to IC and TO. The accuracy and precision of HPA are compared with the gold standard of foot contact event detection, that is, force plate measurements. Furthermore HPA is compared with two other kinematics methods. This study has been conducted on 20 CP children and on eight normal adults. For normal subjects all the methods performed equally well. True errors in HPA (mean+/-standard deviation) were found to be 1+/-23 ms for IC and 2+/-25 ms for TO in CP children. These results were significantly (p<0.05) more accurate and precise than those obtained using the other algorithms. Moreover, in the case of pathological gaits, the other methods are not suitable for IC detection when IC is flatfoot or forefoot. In conclusion, the HPA is a simple and robust algorithm, which performs equally well for adults and actually performs better when applied to the gait of CP children. It is therefore recommended as the method of choice.

Entities:  

Mesh:

Year:  2008        PMID: 18676147     DOI: 10.1016/j.gaitpost.2008.06.009

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  16 in total

1.  Identification of gait events in children with spastic cerebral palsy: comparison between the force plate and algorithms.

Authors:  Rejane Vale Gonçalves; Sérgio Teixeira Fonseca; Priscila Albuquerque Araújo; Vanessa Lara Araújo; Tais Martins Barboza; Gabriela Andrade Martins; Marisa Cotta Mancini
Journal:  Braz J Phys Ther       Date:  2019-06-12       Impact factor: 3.377

2.  Stance and swing phase detection during level and slope walking in the cat: effects of slope, injury, subject and kinematic detection method.

Authors:  Annette Pantall; Robert J Gregor; Boris I Prilutsky
Journal:  J Biomech       Date:  2012-04-06       Impact factor: 2.712

3.  The effects of sub-threshold vibratory noise on visuomotor entrainment during human walking and standing in a virtual reality environment.

Authors:  Samuel A Acuña; John D Zunker; Darryl G Thelen
Journal:  Hum Mov Sci       Date:  2019-06-28       Impact factor: 2.161

4.  An Algorithm for Accurate Marker-Based Gait Event Detection in Healthy and Pathological Populations During Complex Motor Tasks.

Authors:  Tecla Bonci; Francesca Salis; Kirsty Scott; Lisa Alcock; Clemens Becker; Stefano Bertuletti; Ellen Buckley; Marco Caruso; Andrea Cereatti; Silvia Del Din; Eran Gazit; Clint Hansen; Jeffrey M Hausdorff; Walter Maetzler; Luca Palmerini; Lynn Rochester; Lars Schwickert; Basil Sharrack; Ioannis Vogiatzis; Claudia Mazzà
Journal:  Front Bioeng Biotechnol       Date:  2022-06-02

5.  Gait event detection on level ground and incline walking using a rate gyroscope.

Authors:  Paola Catalfamo; Salim Ghoussayni; David Ewins
Journal:  Sensors (Basel)       Date:  2010-06-04       Impact factor: 3.576

6.  A novel HMM distributed classifier for the detection of gait phases by means of a wearable inertial sensor network.

Authors:  Juri Taborri; Stefano Rossi; Eduardo Palermo; Fabrizio Patanè; Paolo Cappa
Journal:  Sensors (Basel)       Date:  2014-09-02       Impact factor: 3.576

7.  Application of a tri-axial accelerometry-based portable motion recorder for the quantitative assessment of hippotherapy in children and adolescents with cerebral palsy.

Authors:  Tomoko Mutoh; Tatsushi Mutoh; Makoto Takada; Misato Doumura; Masayo Ihara; Yasuyuki Taki; Hirokazu Tsubone; Masahiro Ihara
Journal:  J Phys Ther Sci       Date:  2016-10-28

Review 8.  Gait Partitioning Methods: A Systematic Review.

Authors:  Juri Taborri; Eduardo Palermo; Stefano Rossi; Paolo Cappa
Journal:  Sensors (Basel)       Date:  2016-01-06       Impact factor: 3.576

9.  Trunk Kinematic Analysis during Gait in Cerebral Palsy Children with Crouch Gait Pattern.

Authors:  L Abbasi; Z Rojhani-Shirazi; M Razeghi; H Raeisi Shahraki
Journal:  J Biomed Phys Eng       Date:  2018-09-01

10.  What is the Best Configuration of Wearable Sensors to Measure Spatiotemporal Gait Parameters in Children with Cerebral Palsy?

Authors:  Lena Carcreff; Corinna N Gerber; Anisoara Paraschiv-Ionescu; Geraldo De Coulon; Christopher J Newman; Stéphane Armand; Kamiar Aminian
Journal:  Sensors (Basel)       Date:  2018-01-30       Impact factor: 3.576

View more