The sensitivity of motor response to needle nerve stimulation during ultrasound guided interscalene catheter placement.

Michael J Fredrickson1.   

Abstract

BACKGROUND AND OBJECTIVES: Neurostimulation during single shot interscalene block has a significant false negative motor response rate. Compared with tangential needle approaches for single shot block, interscalene catheter (ISC) placement commonly involves Tuohy needles inserted longitudinally to the brachial plexus. This study aimed to determine the sensitivity of neurostimulation during ultrasound-guided ISC needle placement, and the feasibility of an ultrasound-guided ISC needle endpoint.
METHODS: One hundred fifty-five consecutive nonstimulating ISCs were placed with the needle tip position confirmed by the sonographic spread of 5 mL dextrose 5%. Catheter advancement was then blind 2 to 3 cm past the needle tip. A 0.8 mA electrical stimulus at 2 Hz was applied throughout. When a satisfactory image was obtained, neurostimulation was ignored and the minimum motor response amplitude noted. If imaging was equivocal, a brief appropriate motor response at 0.8 mA was sought. A sustained response at <0.5 mA was only sought if imaging was suboptimal. Prior to surgery conducted under general anesthesia, 30 mL ropivacaine 0.5% was administered through the ISC. Catheter success was defined as a recovery room numerical rating pain score of </=2 (scale, 0-10).
RESULTS: In 57% of patients, a muscle response was not elicited. An ultrasound needle endpoint was used in 92% of ISC placements, of which 96% were successful. Sustained twitches at <0.5 mA were obtained in 12 (8%) patients, 6 (4%) of these deliberately sought because of suboptimal imaging. Catheter success overall was 95%.
CONCLUSIONS: This study suggests that the false negative motor response rate for longitudinal ISC needle placement is higher than the false negative response rate associated with tangential needle approach interscalene block. An ultrasound guided ISC needle endpoint is a feasible alternative to a neurostimulation endpoint.

Entities:  

Mesh:

Year:  2008        PMID: 18675738     DOI: 10.1016/j.rapm.2007.12.014

Source DB:  PubMed          Journal:  Reg Anesth Pain Med        ISSN: 1098-7339            Impact factor:   6.288


  10 in total

Review 1.  Upper extremity regional anesthesia: essentials of our current understanding, 2008.

Authors:  Joseph M Neal; J C Gerancher; James R Hebl; Brian M Ilfeld; Colin J L McCartney; Carlo D Franco; Quinn H Hogan
Journal:  Reg Anesth Pain Med       Date:  2009 Mar-Apr       Impact factor: 6.288

2.  Ultrasound-guided perineural catheter insertion: three approaches but few illuminating data.

Authors:  Brian M Ilfeld; Michael J Fredrickson; Edward R Mariano
Journal:  Reg Anesth Pain Med       Date:  2010 Mar-Apr       Impact factor: 6.288

Review 3.  Development of technologies for placement of perineural catheters.

Authors:  Hesham Elsharkawy; Ankit Maheshwari; Ehab Farag; Edward R Mariano; Richard W Rosenquist
Journal:  J Anesth       Date:  2015-09-14       Impact factor: 2.078

4.  Accuracy of ultrasound-guided suprascapular nerve block measured with neurostimulation.

Authors:  Mehmet A Taskaynatan; Ahmet Ozgul; Koray Aydemir; Ozlem Omac Koroglu; Arif K Tan
Journal:  Rheumatol Int       Date:  2011-04-27       Impact factor: 2.631

5.  [Electrical nerve stimulation for peripheral nerve blocks. Ultrasound-guided needle positioning and effect of 5% glucose injection].

Authors:  M Habicher; M Ocken; J Birnbaum; T Volk
Journal:  Anaesthesist       Date:  2009-10       Impact factor: 1.041

6.  The role of continuous peripheral nerve blocks.

Authors:  José Aguirre; Alicia Del Moral; Irina Cobo; Alain Borgeat; Stephan Blumenthal
Journal:  Anesthesiol Res Pract       Date:  2012-06-18

7.  Anesthesiological considerations in shoulder surgery.

Authors:  M Lanna; A Pastore; C Policastro; C Iacovazzo
Journal:  Transl Med UniSa       Date:  2012-04-30

8.  Regional blockade of the shoulder: approaches and outcomes.

Authors:  Clifford Bowens; Ramprasad Sripada
Journal:  Anesthesiol Res Pract       Date:  2012-06-25

9.  Current concepts in anaesthesia for shoulder surgery.

Authors:  Lutfi Sulaiman; Robert J Macfarlane; Mohammad Waseem
Journal:  Open Orthop J       Date:  2013-09-06

10.  No correlation between minimal electrical charge at the tip of the stimulating catheter and the efficacy of the peripheral nerve block catheter for brachial plexus block: a prospective blinded cohort study.

Authors:  Karin Pw Schoenmakers; Petra Jc Heesterbeek; Nigel Tm Jack; Rudolf Stienstra
Journal:  BMC Anesthesiol       Date:  2014-04-11       Impact factor: 2.217

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.