Literature DB >> 18675550

Protontherapy of eye tumours in the UK: a review of treatment at Clatterbridge.

A Kacperek1.   

Abstract

The Scanditronix MC-60 PF cyclotron at Clatterbridge was commissioned in 1984 for fast neutrontherapy trials. It also produced a 60.0 MeV clinical beam suitable for treating ocular tumours with a maximum penetration of 31 mm (water) and a 0.9 mm fall-off. An additional treatment room was built with an ocular beamline constructed in-house. The first group of eye patients was treated in June 1989, making this the first hospital-based proton facility. More than 1700 eye patients have been treated by the only UK proton service.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18675550     DOI: 10.1016/j.apradiso.2008.06.012

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  7 in total

1.  Proton beam therapy for presumed and confirmed iris melanomas: a review of 36 cases.

Authors:  Ahmed Rahmi; Hamid Mammar; Juliette Thariat; Gaelle Angellier; Joel Herault; Pierre Chauvel; Laurent Kodjikian; Philippe Denis; Jean Daniel Grange
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-07-20       Impact factor: 3.117

2.  Modelling the throughput capacity of a single-accelerator multitreatment room proton therapy centre.

Authors:  A H Aitkenhead; D Bugg; C G Rowbottom; E Smith; R I Mackay
Journal:  Br J Radiol       Date:  2012-12       Impact factor: 3.039

3.  Comparison of the light charged particles on scatter radiation dose in thyroid hadron therapy.

Authors:  M Azizi; Aa Mowlavi
Journal:  J Biomed Phys Eng       Date:  2014-09-01

4.  Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera.

Authors:  Mansour Almurayshid; Yusuf Helo; Andrzej Kacperek; Jennifer Griffiths; Jem Hebden; Adam Gibson
Journal:  J Appl Clin Med Phys       Date:  2017-07-29       Impact factor: 2.102

5.  Three-dimensional MRI-based treatment planning approach for non-invasive ocular proton therapy.

Authors:  E Fleury; P Trnková; E Erdal; M Hassan; B Stoel; M Jaarma-Coes; G Luyten; J Herault; A Webb; J-W Beenakker; J-P Pignol; M Hoogeman
Journal:  Med Phys       Date:  2021-01-17       Impact factor: 4.071

6.  Variations in the Processing of DNA Double-Strand Breaks Along 60-MeV Therapeutic Proton Beams.

Authors:  Pankaj Chaudhary; Thomas I Marshall; Frederick J Currell; Andrzej Kacperek; Giuseppe Schettino; Kevin M Prise
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-07-29       Impact factor: 7.038

7.  Complex DNA Damage Induced by High Linear Energy Transfer Alpha-Particles and Protons Triggers a Specific Cellular DNA Damage Response.

Authors:  Rachel J Carter; Catherine M Nickson; James M Thompson; Andrzej Kacperek; Mark A Hill; Jason L Parsons
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-11-14       Impact factor: 7.038

  7 in total