Literature DB >> 18672358

Extended-gate FET-based enzyme sensor with ferrocenyl-alkanethiol modified gold sensing electrode.

Yu Ishige1, Maki Shimoda, Masao Kamahori.   

Abstract

We developed a field-effect transistor (FET)-based enzyme sensor that detects an enzyme-catalyzed redox-reaction event as an interfacial potential change on an 11-ferrocenyl-1-undecanethiol (11-FUT) modified gold electrode. While the sensitivity of ion-sensitive FET (ISFET)-based enzyme sensors that detect an enzyme-catalyzed reaction as a local pH change are strongly affected by the buffer conditions such as pH and buffer capacity, the sensitivity of the proposed FET-based enzyme sensor is not affected by them in principle. The FET-based enzyme sensor consists of a detection part, which is an extended-gate FET sensor with an 11-FUT immobilized gold electrode, and an enzyme reaction part. The FET sensor detected the redox reaction of hexacyanoferrate ions, which are standard redox reagents of an enzymatic assay in blood tests, as a change in the interfacial potential of the 11-FUT modified gold electrode in accordance with the Nernstian response at a slope of 59 mV/decade at 25 degrees C. Also, the FET sensor had a dynamic range of more than five orders and showed no sensitivity to pH. A FET-based enzyme sensor for measuring cholesterol level was constructed by adding an enzyme reaction part, which contained cholesterol dehydrogenase and hexacyanoferrate (II)/(III) ions, on the 11-FUT modified gold electrode. Since the sensitivity of the FET sensor based on potentiometric detection was independent of the sample volume, the sample volume was easily reduced to 2.5 microL while maintaining the sensitivity. The FET-based enzyme sensor successfully detected a serum cholesterol level from 33 to 233 mg/dL at the Nernstian slope of 57 mV/decade.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18672358     DOI: 10.1016/j.bios.2008.06.012

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

Review 1.  Molecular analysis of blood with micro-/nanoscale field-effect-transistor biosensors.

Authors:  Matthew S Makowski; Albena Ivanisevic
Journal:  Small       Date:  2011-06-03       Impact factor: 13.281

2.  Chemistry integrated circuit: chemical system on a complementary metal oxide semiconductor integrated circuit.

Authors:  Kazuo Nakazato
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2014-02-24       Impact factor: 4.226

3.  Ion-sensitive field-effect transistor for biological sensing.

Authors:  Chang-Soo Lee; Sang Kyu Kim; Moonil Kim
Journal:  Sensors (Basel)       Date:  2009-09-07       Impact factor: 3.576

Review 4.  Catabolism and biotechnological applications of cholesterol degrading bacteria.

Authors:  J L García; I Uhía; B Galán
Journal:  Microb Biotechnol       Date:  2012-02-07       Impact factor: 5.813

  4 in total