Literature DB >> 18670325

The effect of cerebrospinal fluid on the biomechanics of spinal cord: an ex vivo bovine model using bovine and physical surrogate spinal cord.

Claire F Jones1, Shannon G Kroeker, Peter A Cripton, Richard M Hall.   

Abstract

STUDY
DESIGN: A biomechanical study using ex vivo bovine spinal cord and dura, and a synthetic surrogate spinal cord with bovine dura.
OBJECTIVE: To investigate the effect of cerebrospinal fluid (CSF) on spinal cord deformation characteristics and to evaluate the biofidelity of a new surrogate spinal cord using an ex vivo bovine model of the burst fracture process. SUMMARY OF BACKGROUND DATA: Spinal cord injury is associated with significant personal, economic and social costs. The role of CSF during the injury event and its effect on the spinal cord deformation and neurologic injury is not well understood. Such knowledge could inform preventative strategies and clinical interventions and aid the development and validation of experimental and computational models.
METHODS: The transverse impact of a propelled bone fragment analogue with bovine and surrogate cord models was recorded with high speed video and the images analyzed to determine deformation trajectories. Each cord specimen was tested in 3 states: with dura and CSF, with dura only, and without dura. The effect of these states on deformation magnitude, duration, and energy loss parameters was assessed. RESULTS.: The estimated spinal cord deformation was significantly reduced, although not eliminated, in the presence of CSF when compared to the bare state. The duration of deformation was generally increased in the presence of CSF, though this difference was not statistically significant. This may indicate a reduction in the cord-fragment interaction force for a given impulse. The dura was found to have no significant effect on deformation parameters for the bovine spinal cord. The deformation of the surrogate cord gave similar trends for the different states in comparison to the bovine cord, but was significantly less than the bovine spinal cord for all conditions.
CONCLUSION: The results indicate that the protective mechanism of CSF may not eliminate cord deformationunder the high energy transverse impact characteristic of a burst fracture. However, CSF may contribute to a lessening of cord deformation and applied force.

Entities:  

Mesh:

Year:  2008        PMID: 18670325     DOI: 10.1097/BRS.0b013e31817ecc57

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  5 in total

1.  The morphological and clinical significance of developmental cervical stenosis.

Authors:  Miao Yu; Yanchao Tang; Zhongjun Liu; Yu Sun; Xiaoguang Liu
Journal:  Eur Spine J       Date:  2015-03-27       Impact factor: 3.134

2.  Damage Accumulation Modeling and Rate Dependency of Spinal Dura Mater.

Authors:  Nicole Ramo; Snehal S Shetye; Christian M Puttlitz
Journal:  J Eng Sci Med Diagn Ther       Date:  2017-11-21

3.  Development of surrogate spinal cords for the evaluation of electrode arrays used in intraspinal implants.

Authors:  Cheng Cheng; Jonn Kmech; Vivian K Mushahwar; Anastasia L Elias
Journal:  IEEE Trans Biomed Eng       Date:  2013-01-23       Impact factor: 4.538

4.  Rat model of spinal cord injury preserving dura mater integrity and allowing measurements of cerebrospinal fluid pressure and spinal cord blood flow.

Authors:  Marc Soubeyrand; Elisabeth Laemmel; Charles Court; Arnaud Dubory; Eric Vicaut; Jacques Duranteau
Journal:  Eur Spine J       Date:  2013-03-19       Impact factor: 3.134

5.  A New Framework for Investigating the Biological Basis of Degenerative Cervical Myelopathy [AO Spine RECODE-DCM Research Priority Number 5]: Mechanical Stress, Vulnerability and Time.

Authors:  Benjamin M Davies; Oliver Mowforth; Aref-Ali Gharooni; Lindsay Tetreault; Aria Nouri; Rana S Dhillon; Josef Bednarik; Allan R Martin; Adam Young; Hitoshi Takahashi; Timothy F Boerger; Virginia Fj Newcombe; Carl Moritz Zipser; Patrick Freund; Paul Aarne Koljonen; Ricardo Rodrigues-Pinto; Vafa Rahimi-Movaghar; Jefferson R Wilson; Shekar N Kurpad; Michael G Fehlings; Brian K Kwon; James S Harrop; James D Guest; Armin Curt; Mark R N Kotter
Journal:  Global Spine J       Date:  2022-02