Literature DB >> 18670286

Semitubular plates for acutely displaced midclavicular fractures: a retrospective study of 111 patients followed for 2.5 to 6 years.

Chung-Hwan Chen1, Jian-Chih Chen, Chihuei Wang, Yin-Chun Tien, Je-Ken Chang, Shao-Hung Hung.   

Abstract

OBJECTIVES: We designed this study to determine the usefulness of semitubular plates for acute displaced or comminuted fractures of the midclavicle.
DESIGN: Nonrandomized retrospective study.
SETTING: A secondary transfer hospital specializing in orthopaedics. PATIENTS: From May 1997 to July 2001, 121 patients were treated with a 92% (111) follow-up rate. The mean follow-up time was 3.5 years (range, 2.5 to 6 years). INTERVENTION: Semitubular plates using 4.5-mm cortical or 6.5-mm cancellous screws and wire as necessary. MAIN OUTCOME MEASUREMENT: The functional result was evaluated by the Disabilities of the Arm, Shoulder and Hand (DASH) score at the time of admission for implant removal in 82 patients or at the end of follow-up by telephone in 29 patients.
RESULTS: Most (107 of 111) fractures healed within 6 months. Three patients with implant failure due to backing out of the screws healed after surgical revision. One patient had an infected nonunion with a poor result. The other 110 patients had good results. No implant breakage was noted. No other major complications were noted except for 1 deep infection. No bone graft was needed, even with comminution at the fracture site. Of the 107 patients with uneventful union, 82 had hardware removal. The other 25 were diagnosed as having union both radiographically and clinically and did not have their hardware removed.
CONCLUSION: Overall, 95% of patients were satisfied with the surgical procedure. We suggest that a semitubular plate with 4.5-mm cortical and 6.5-mm cancellous screws with wire augmentation if necessary is a reliable procedure for acute severely displaced or comminuted midclavicular fractures.

Entities:  

Mesh:

Year:  2008        PMID: 18670286     DOI: 10.1097/BOT.0b013e31817996fc

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  4 in total

1.  Precontoured plating of clavicle fractures: decreased hardware-related complications?

Authors:  Corinne VanBeek; Karen J Boselli; Edwin R Cadet; Christopher S Ahmad; William N Levine
Journal:  Clin Orthop Relat Res       Date:  2011-12       Impact factor: 4.176

2.  Displaced mid-shaft clavicular fractures: surgical treatment with a pre-contoured angular stability plate.

Authors:  Gabriele Campochiaro; Christos Tsatsis; Gabriele Gazzotti; Manuela Rebuzzi; Fabio Catani
Journal:  Musculoskelet Surg       Date:  2012-04-21

3.  Function plateaus by one year in patients with surgically treated displaced midshaft clavicle fractures.

Authors:  Laura A Schemitsch; Emil H Schemitsch; Christian Veillette; Rad Zdero; Michael D McKee
Journal:  Clin Orthop Relat Res       Date:  2011-12       Impact factor: 4.176

4.  TREATMENT OF MIDSHAFT CLAVICLE FRACTURE WITH SUPERIOR PLATE PLACEMENT.

Authors:  Bekir Eray Kilinc; Yunus Oc; Ramazan Erden Erturer
Journal:  Acta Ortop Bras       Date:  2020 Mar-Apr       Impact factor: 0.513

  4 in total