Literature DB >> 18670054

In-beam PET measurement of 7Li3+ irradiation induced beta+-activity.

M Priegnitz1, D Möckel, K Parodi, F Sommerer, F Fiedler, W Enghardt.   

Abstract

At present positron emission tomography (PET) is the only feasible method of an in situ and non-invasive monitoring of patient irradiation with ions. At the experimental carbon ion treatment facility of the Gesellschaft für Schwerionenforschung (GSI) Darmstadt an in-beam PET scanner has been integrated into the treatment site and lead to a considerable quality improvement of the therapy. Since ions other than carbon are expected to come into operation in future patient treatment facilities, it is highly desirable to extend in-beam PET also to other therapeutic relevant ions, e.g. (7)Li. Therefore, by means of the in-beam PET scanner at GSI the beta(+)-activity induced by (7)Li(3+) ions has been investigated for the first time. Targets of PMMA, water, graphite and polyethylene were irradiated with monoenergetic, pencil-like beams of (7)Li(3+) with energies between 129.1 A MeV and 205.3 A MeV and intensities ranging from 3.0 x 10(7) to 1.9 x 10(8) ions s(-1). This paper presents the measured beta(+)-activity profiles as well as depth dependent thick target yields which have been deduced from the experimental data. The beta(+)-activity induced by (7)Li ions was found to be a factor of 1.76 higher than the one induced by (12)C ions at the same physical dose and particle range.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18670054     DOI: 10.1088/0031-9155/53/16/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

Review 1.  Positron emission tomography imaging approaches for external beam radiation therapies: current status and future developments.

Authors:  P M Price; M M Green
Journal:  Br J Radiol       Date:  2011-03-22       Impact factor: 3.039

Review 2.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

Review 3.  Monitoring of Hadrontherapy Treatments by Means of Charged Particle Detection.

Authors:  Silvia Muraro; Giuseppe Battistoni; Francesco Collamati; Erika De Lucia; Riccardo Faccini; Fernando Ferroni; Salvatore Fiore; Paola Frallicciardi; Michela Marafini; Ilaria Mattei; Silvio Morganti; Riccardo Paramatti; Luca Piersanti; Davide Pinci; Antoni Rucinski; Andrea Russomando; Alessio Sarti; Adalberto Sciubba; Elena Solfaroli-Camillocci; Marco Toppi; Giacomo Traini; Cecilia Voena; Vincenzo Patera
Journal:  Front Oncol       Date:  2016-08-03       Impact factor: 6.244

Review 4.  Range Verification Methods in Particle Therapy: Underlying Physics and Monte Carlo Modeling.

Authors:  Aafke Christine Kraan
Journal:  Front Oncol       Date:  2015-07-07       Impact factor: 6.244

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.