Literature DB >> 18669765

Robotic trocar site small bowel evisceration after gynecologic cancer surgery.

Leigh G Seamon1, Floor Backes, Kimberly Resnick, David E Cohn.   

Abstract

BACKGROUND: Trocar site hernia is a known, rare complication after laparoscopic surgery. We describe a case of bowel herniation, evisceration, and bowel obstruction through an 8-mm robotic port site. CASE: A 67-year-old patient with endometrial cancer underwent an uncomplicated robotic hysterectomy, bilateral salpingo-oophorectomy, and pelvic and aortic lymphadenectomy. Four days later, she presented with symptoms of a small bowel obstruction and was found to have evisceration through a laterally placed 8-mm robotic port site. The bowel was reduced locally and the fascial defect repaired without midline laparotomy or bowel resection.
CONCLUSION: Bowel herniation can occur through the fascial defect after placement of an 8-mm robotic port. Continued reporting is needed to accurately gauge the occurrence of this complication.

Entities:  

Mesh:

Year:  2008        PMID: 18669765     DOI: 10.1097/AOG.0b013e3181719ba8

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  12 in total

1.  Recent advances of robotic surgery and single port laparoscopy in gynecologic oncology.

Authors:  Yong Wook Jung; Sang Wun Kim; Young Tae Kim
Journal:  J Gynecol Oncol       Date:  2009-09-30       Impact factor: 4.401

2.  Trocar-site hernia at the 8-mm robotic port after robot-assisted laparoscopic prostatectomy: a case report and review of the literature.

Authors:  James Hok-Leung Tsu; Ada Tsui-Lin Ng; Jason Ka-Wing Wong; Edmond Ming-Ho Wong; Kwan-Lun Ho; Ming-Kwong Yiu
Journal:  J Robot Surg       Date:  2013-03-03

3.  High incidence of trocar site hernia after laparoscopic or robotic Roux-en-Y gastric bypass.

Authors:  Gitana Scozzari; Marcello Zanini; Francesca Cravero; Roberto Passera; Fabrizio Rebecchi; Mario Morino
Journal:  Surg Endosc       Date:  2014-05-02       Impact factor: 4.584

4.  Port-site incisional hernia from an 8-mm robotic trocar following robot-assisted radical cystectomy: Report of a rare case.

Authors:  Shoko Uketa; Yousuke Shimizu; Kosuke Ogawa; Noriaki Utsunomiya; Sojun Kanamaru
Journal:  IJU Case Rep       Date:  2020-03-21

5.  Herniation formation in women undergoing robotically assisted laparoscopy or laparotomy for endometrial cancer.

Authors:  Maria B Schiavone; Maciej S Bielen; Ginger J Gardner; Oliver Zivanovic; Elizabeth L Jewell; Yukio Sonoda; Richard R Barakat; Dennis S Chi; Nadeem R Abu-Rustum; Mario M Leitao
Journal:  Gynecol Oncol       Date:  2016-01-08       Impact factor: 5.482

6.  Incidence of trocar site herniation following robotic gynecologic surgery.

Authors:  Leslie H Clark; Pamela T Soliman; Diego Odetto; Mark F Munsell; Kathleen M Schmeler; Nicole Fleming; Shannon N Westin; Alpa M Nick; Pedro T Ramirez
Journal:  Gynecol Oncol       Date:  2013-08-27       Impact factor: 5.482

7.  A rare case of acute presentation of trocar site hernia from robot-assisted laparoscopic partial nephrectomy.

Authors:  Zi Qin Ng; Richard Pemberton; Patrick Tan
Journal:  J Robot Surg       Date:  2018-02-15

8.  Robotic single-port transumbilical total hysterectomy: a pilot study.

Authors:  Eun Ji Nam; Sang Wun Kim; Maria Lee; Ga Won Yim; Ji Heum Paek; San Hui Lee; Sunghoon Kim; Jae Hoon Kim; Jae Wook Kim; Young Tae Kim
Journal:  J Gynecol Oncol       Date:  2011-06-30       Impact factor: 4.401

9.  Perioperative complications of robot-assisted laparoscopic surgery using three robotic arms at a single institution.

Authors:  Ga Won Yim; Sang Wun Kim; Eun Ji Nam; Sunghoon Kim; Young Tae Kim
Journal:  Yonsei Med J       Date:  2015-03       Impact factor: 2.759

10.  Novel port placement and 5-mm instrumentation for robotic-assisted hysterectomy.

Authors:  Ceana H Nezhat; Adi Katz; Erica C Dun; Kimberly A Kho; Friedrich A Wieser
Journal:  JSLS       Date:  2014 Apr-Jun       Impact factor: 2.172

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.