Literature DB >> 18667862

Improvement of virus safety of an antihemophilc factor IX by virus filtration process.

In Seop Kim1, Yong Woon Choi, Yong Kang, Hark Mo Sung, Ki Whan Sohn, Yong-Sung Kim.   

Abstract

Viral safety is an important prerequisite for clinical preparations of plasma-derived pharmaceuticals. One potential way to increase the safety of therapeutic biological products is the use of a virus-retentive filter. In order to increase the viral safety of human antihemophilic factor IX, particularly in regard to non-enveloped viruses, virus removal process using a polyvinylidene fluoride membrane filter (Viresolve NFP) has been optimized. The most critical factor affecting the filtration efficiency was operating pH and the optimum pH was 6 or 7. Flow rate increased with increasing operating pressure and temperature. Recovery yield in the optimized production-scale process was 96%. No substantial changes were observed in the physical and biochemical characteristics of the filtered factor IX in comparison with those before filtration. A 47-mm disk membrane filter was used to simulate the process performance of the production-scale cartridges and to test if it could remove several experimental model viruses for human pathogenic viruses, including human hepatitis A virus (HAV), porcine parvovirus (PPV), murine encephalomyocarditis virus (EMCV), human immunodeficiency virus type 1 (HIV), bovine viral diarrhea virus (BVDV), and bovine herpes virus (BHV). Nonenveloped viruses (HAV, PPV, and EMCV) as well as enveloped viruses (HIV, BVDV, and BHV) were completely removed during filtration. The log reduction factors achieved were >or=6.12 for HAV, >or=4.28 for PPV, >or=5.33 for EMCV, >or=5.51 for HIV, >or=5.17 for BVDV, and >or=5.75 for BHV. These results indicate that the virus filtration process successfully improved the viral safety of factor IX.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18667862

Source DB:  PubMed          Journal:  J Microbiol Biotechnol        ISSN: 1017-7825            Impact factor:   2.351


  4 in total

Review 1.  BAX326 (RIXUBIS): a novel recombinant factor IX for the control and prevention of bleeding episodes in adults and children with hemophilia B.

Authors:  Jerzy Windyga; Maria Helena Solano Trujillo; Andrea E Hafeman
Journal:  Ther Adv Hematol       Date:  2014-10

Review 2.  Once-weekly prophylactic dosing of recombinant factor IX improves adherence in hemophilia B.

Authors:  Claudia Djambas Khayat
Journal:  J Blood Med       Date:  2016-11-30

3.  Two-Step Size-Exclusion Nanofiltration of Prothrombin Complex Concentrate Using Nanocellulose-Based Filter Paper.

Authors:  Levon Manukyan; Athanasios Mantas; Mikhail Razumikhin; Andrey Katalevsky; Eugen Golubev; Albert Mihranyan
Journal:  Biomedicines       Date:  2020-03-26

4.  Isoporous Polyvinylidene Fluoride Membranes with Selective Skin Layers via a Thermal-Vapor Assisted Phase Separation Method for Industrial Purification Applications.

Authors:  Da Han Choi; Sei Kwon; Youngmin Yoo; In-Chul Kim; Hosik Park; You-In Park; Sung Yun Yang; Seung-Eun Nam; Young Hoon Cho
Journal:  Membranes (Basel)       Date:  2022-02-22
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.