Literature DB >> 18667298

Invertase inhibition based electrochemical sensor for the detection of heavy metal ions in aqueous system: Application of ultra-microelectrode to enhance sucrose biosensor's sensitivity.

Dipali Bagal-Kestwal1, Meena S Karve, Bhalchandra Kakade, Vijayamohanan K Pillai.   

Abstract

We are reporting fabrication and characterization of electrochemical sucrose biosensor using ultra-microelectrode (UME) for the detection of heavy metal ions (Hg(II), Ag(I), Pb(II) and Cd(II)). The working UME, with 25 microm diameter, was modified with invertase (INV, EC: 3.2.1.26) and glucose oxidase (GOD, EC: 1.1.3.4) entrapped in agarose-guar gum. The hydrophilic character of the agarose-guar gum composite matrix was checked by water contact angle measurement. The atomic force microscopy (AFM) images of the membranes showed proper confinement of both the enzymes during co-immobilization. The dynamic range for sucrose biosensor was achieved in the range of 1 x 10(-10) to 1 x 10(-7)M with lower detection limit 1 x 10(-10)M at pH 5.5 with 9 cycles of reuse. The spectrophotometric and electrochemical studies showed linear relationship between concentration of heavy metal ions and degree of inhibition of invertase. The toxicity sequence for invertase using both methods was observed as Hg(2+)>Pb(2+)>Ag(+)>Cd(2+). The dynamic linear range for mercury using electrochemical biosensor was observed in the range of 5 x 10(-10) to 12.5 x 10(-10)M for sucrose. The lower detection limit for the fabricated biosensor was found to be 5 x 10(-10)M. The reliability of the electrochemical biosensor was conformed by testing the spike samples and the results were comparable with the conventional photometric DNSA method.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18667298     DOI: 10.1016/j.bios.2008.06.027

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  9 in total

1.  Amperometric determination of As(III) and Cd(II) using a platinum electrode modified with acetylcholinesterase, ruthenium(II)-tris(bipyridine) and graphene oxide.

Authors:  Manju Bhargavi Gumpu; Murugan Veerapandian; Uma Maheswari Krishnan; John Bosco Balaguru Rayappan
Journal:  Mikrochim Acta       Date:  2018-05-12       Impact factor: 5.833

Review 2.  Recent trends in monitoring of European water framework directive priority substances using micro-sensors: a 2007-2009 review.

Authors:  Philippe Namour; Mathieu Lepot; Nicole Jaffrezic-Renault
Journal:  Sensors (Basel)       Date:  2010-08-26       Impact factor: 3.576

3.  A high sensitivity micro format chemiluminescence enzyme inhibition assay for determination of Hg(II).

Authors:  Kanchanmala Deshpande; Rupesh K Mishra; Sunil Bhand
Journal:  Sensors (Basel)       Date:  2010-06-28       Impact factor: 3.576

Review 4.  Modified electrodes used for electrochemical detection of metal ions in environmental analysis.

Authors:  Gregory March; Tuan Dung Nguyen; Benoit Piro
Journal:  Biosensors (Basel)       Date:  2015-04-29

5.  A Simple, Cost-Effective Sensor for Detecting Lead Ions in Water Using Under-Potential Deposited Bismuth Sub-Layer with Differential Pulse Voltammetry (DPV).

Authors:  Yifan Dai; Chung Chiun Liu
Journal:  Sensors (Basel)       Date:  2017-04-25       Impact factor: 3.576

6.  Carbon Quantum Dots Based Chemosensor Array for Monitoring Multiple Metal Ions.

Authors:  Tianlei Qin; Jiayi Wang; Yuanli Liu; Song Guo
Journal:  Molecules       Date:  2022-06-15       Impact factor: 4.927

7.  Characterization of an invertase with pH tolerance and truncation of its N-terminal to shift optimum activity toward neutral pH.

Authors:  Liqin Du; Hao Pang; Zilong Wang; Jian Lu; Yutuo Wei; Ribo Huang
Journal:  PLoS One       Date:  2013-04-19       Impact factor: 3.240

Review 8.  Exploration of Chitinous Scaffold-Based Interfaces for Glucose Sensing Assemblies.

Authors:  Dipali R Bagal-Kestwal; Been-Huang Chiang
Journal:  Polymers (Basel)       Date:  2019-11-28       Impact factor: 4.329

9.  Identification of an exposure risk to heavy metals from pharmaceutical-grade rubber stoppers.

Authors:  Xianghui Li; Pingping Qian
Journal:  J Food Drug Anal       Date:  2016-11-02       Impact factor: 6.157

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.