Literature DB >> 18666216

Intracoronary MR imaging using a 0.014-inch MR imaging-guidewire: toward MRI-guided coronary interventions.

Bensheng Qiu1, Fabao Gao, Parag Karmarkar, Ergin Atalar, Xiaoming Yang.   

Abstract

PURPOSE: To validate the feasibility of using a newly designed MR imaging-guidewire (MRIG) to guide angioplasty balloon placement in coronary arteries.
MATERIALS AND METHODS: A custom gold/sliver/Nitinol/MP35N-based, 0.014-inch MRIG was manufactured. To test its mechanical performance we used the new MRIG to catheterize the left coronary arteries of three dogs under x-ray fluoroscopy. To further validate the feasibility of using the MRIG to generate intracoronary MR imaging, we positioned the MRIG, along with a dilation-perfusion balloon catheter, into the left coronary arteries of an additional three dogs. Longitudinal and four-chamber views of cine cardiac MR images were obtained using a fast gradient recalled echo (FGRE) sequence (TR/TE/FA = 5.2 msec/1.6 msec/20 degrees , field of view [FOV] = 32 x 32 cm, thickness = 5 mm, space = 2 mm, matrix = 256 x 160, number of excites [NEX] = 0.5, and bandwidth [BW] = 32 kHz). Then three-dimensional (3D) MR coronary angiography of the left coronary arteries was obtained using a fast imaging employing steady-state acquisition (FIESTA) sequence. We subsequently used the MRIG, at a receive-only mode, to generate intracoronary MR images using FGRE (TR/TE/FA = 7.2 msec/3.5 msec/20 degrees , FOV = 18 x 18cm, thickness = 3 mm, space = 0.5 mm, matrix = 256 x 256, NEX = 0.5, and BW = 32 kHz).
RESULTS: In all six animals the left main coronary arteries were successfully catheterized. 3D MR imaging displayed left coronary artery branches. Intracoronary MR imaging demonstrated the inflated balloons as a "train track" or a bright, thick ring at different views.
CONCLUSION: This study demonstrates the potential of using this newly designed gold/sliver/Nitinol/MP35N-based, 0.014-inch MRIG to catheterize coronary arteries and, thus, generate intracoronary MR imaging with balloon inflation. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18666216     DOI: 10.1002/jmri.21424

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  4 in total

Review 1.  Vulnerable plaque imaging-current techniques.

Authors:  K Chad Hilty; Daniel H Steinberg
Journal:  J Cardiovasc Transl Res       Date:  2009-01-14       Impact factor: 4.132

2.  High-resolution intravascular magnetic resonance imaging of the coronary artery wall at 3.0 Tesla: toward evaluation of atherosclerotic plaque vulnerability.

Authors:  Yanfeng Meng; Zhiguang Mo; Jinying Hao; Yueyou Peng; Hui Yan; Jingbo Mu; Dengfeng Ma; Xiaoliang Zhang; Ye Li
Journal:  Quant Imaging Med Surg       Date:  2021-11

3.  Intracardiac MR imaging (ICMRI) guiding-sheath with amplified expandable-tip imaging and MR-tracking for navigation and arrythmia ablation monitoring: Swine testing at 1.5 and 3T.

Authors:  Ehud J Schmidt; Gregory Olson; Junichi Tokuda; Akbar Alipour; Ronald D Watkins; Eric M Meyer; Hassan Elahi; William G Stevenson; Jeffrey Schweitzer; Charles L Dumoulin; Thomas Johnson; Aravindan Kolandaivelu; Wolfgang Loew; Henry R Halperin
Journal:  Magn Reson Med       Date:  2022-02-10       Impact factor: 3.737

4.  Interventional cardiac magnetic resonance imaging: current applications, technology readiness level, and future perspectives.

Authors:  Sophie C Rier; Suzan Vreemann; Wouter H Nijhof; Vincent J H M van Driel; Ivo A C van der Bilt
Journal:  Ther Adv Cardiovasc Dis       Date:  2022 Jan-Dec
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.