Literature DB >> 18666111

Asymmetric quadrature split birdcage coil for hyperpolarized 3He lung MRI at 1.5T.

Nicola De Zanche1, Navjeet Chhina, Kevin Teh, Chris Randell, Klaas P Pruessmann, Jim M Wild.   

Abstract

An asymmetric quadrature birdcage body coil for hyperpolarized (HP) (3)He lung imaging at 1.5T is presented. The coil is designed to rest on top of the patient support and be used as a temporary insert in a clinical system. A two-part construction facilitates patient access and the asymmetric design makes maximal use of available bore space to ensure comfort. Highly homogeneous, circularly polarized RF magnetic fields are produced at 48.5 MHz using a conformal mapping method for the geometrical design, combined with an algebraic method to calculate the individual capacitance values on the birdcage coil's ladder network. Efficiency and isolation from the system's proton body coil are ensured by an integrated RF screen. The design methodology is readily applicable to other field strengths or nuclei. Improvements over existing (3)He coils were found in terms of sensitivity and transmit field homogeneity, an important feature in HP MRI. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18666111     DOI: 10.1002/mrm.21664

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Simulation Study of Radio Frequency Safety and the Optimal Size of a Single-Channel Surface Radio Frequency Coil for Mice at 9.4 T Magnetic Resonance Imaging.

Authors:  Jeung-Hoon Seo; Yeunchul Ryu; Jun-Young Chung
Journal:  Sensors (Basel)       Date:  2022-06-03       Impact factor: 3.847

2.  Rapid 3-D mapping of hyperpolarized 3He spin-lattice relaxation times using variable flip angle gradient echo imaging with application to alveolar oxygen partial pressure measurement in rat lungs.

Authors:  Alexei V Ouriadov; Wilfred W Lam; Giles E Santyr
Journal:  MAGMA       Date:  2009-08-04       Impact factor: 2.310

3.  32-channel phased-array receive with asymmetric birdcage transmit coil for hyperpolarized xenon-129 lung imaging.

Authors:  Isabel Dregely; Iulian C Ruset; Graham Wiggins; Azma Mareyam; John P Mugler; Talissa A Altes; Craig Meyer; Kai Ruppert; Lawrence L Wald; F William Hersman
Journal:  Magn Reson Med       Date:  2012-11-06       Impact factor: 4.668

4.  RF instrumentation for same-breath triple nuclear lung MR imaging of (1)H and hyperpolarized (3)He and (129)Xe at 1.5T.

Authors:  Madhwesha Rao; Jim M Wild
Journal:  Magn Reson Med       Date:  2015-05-13       Impact factor: 4.668

Review 5.  In vivo methods and applications of xenon-129 magnetic resonance.

Authors:  Helen Marshall; Neil J Stewart; Ho-Fung Chan; Madhwesha Rao; Graham Norquay; Jim M Wild
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2020-12-09       Impact factor: 9.795

6.  An image acquisition and registration strategy for the fusion of hyperpolarized helium-3 MRI and x-ray CT images of the lung.

Authors:  Rob H Ireland; Neil Woodhouse; Nigel Hoggard; James A Swinscoe; Bernadette H Foran; Matthew Q Hatton; Jim M Wild
Journal:  Phys Med Biol       Date:  2008-10-09       Impact factor: 3.609

Review 7.  Fluorine-19 MRI Contrast Agents for Cell Tracking and Lung Imaging.

Authors:  Matthew S Fox; Jeffrey M Gaudet; Paula J Foster
Journal:  Magn Reson Insights       Date:  2016-03-22

8.  Optimization of steady-state free precession MRI for lung ventilation imaging with 19 F C3 F8 at 1.5T and 3T.

Authors:  Adam Maunder; Madhwesha Rao; Fraser Robb; Jim M Wild
Journal:  Magn Reson Med       Date:  2018-11-02       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.