Early clinical experience with the E-vita thoracic stent-graft system: a single center study.

B Zipfel1, S Buz, R Hammerschmidt, T Krabatsch, V Duesterhoeft, R Hetzer.   

Abstract

AIM: The aim of this study was to evaluate the safety and efficacy of a new endovascular thoracic stent-graft, which was designed to overcome the restrictions of previously used stent-grafts.
METHODS: Between May 2004 and March 2008 a prospective evaluation was conducted in 126 consecutive patients (71% men; age 64 [19-86] years). A total of 138 implantations were performed. E-vita stent-grafts were implanted for type-B dissection (N.=56), degenerative aneurysm (N.=25), penetrating aortic ulcer (N.=17), blunt traumatic lesions (N.=10), mobile atheroma (N.=1), suture aneurysms (N.=7) and revisionary surgery following previous endograft implantation (N.=22). All patients eligible for stent-grafting were treated with this system regardless of their clinical status and aortic pathology. The percentage of emergency procedures was 52% (N.=72). Per implantation a mean of 1.3 segments was implanted with an effective total covered length of the aorta of mean 204 mm, median 230 mm (0-450 mm). In 32 of 39 cases with more than one segment, the entire descending aorta was included in the procedure.
RESULTS: The 30-day mortality rate was 12.3% (17 patients). All deaths but one were in the group of emergency surgery patients. This results in mortality of 1.5% in the elective and 22% in the emergency procedures. Reversible procedure-induced spinal cord ischemia was observed in 2 cases. Stroke occurred in 2.8% (4 patients). Primary technical success was rated at 77 % (106 procedures) and secondary success at 89 % (124 procedures).
CONCLUSION: All forms of thoracic aortic disease can be treated with this new stent-graft. It has proved particularly valuable in cases of difficult conditions in the aortic arch and extended aneurysms. In particular, it is possible to cover the entire thoracic aorta with two or three stent-graft segments, thus considerably reducing the number of connections.

Entities:  

Mesh:

Year:  2008        PMID: 18665105

Source DB:  PubMed          Journal:  J Cardiovasc Surg (Torino)        ISSN: 0021-9509            Impact factor:   1.888


  3 in total

Review 1.  Aortic arch plaque in stroke.

Authors:  Souvik Sen
Journal:  Curr Cardiol Rep       Date:  2009-01       Impact factor: 2.931

2.  The combined use of multilayer flow modulator stent and conventional stent grafts in complex thoracoabdominal aortic aneurysms and Type 3 dissections accompanying aneurysms.

Authors:  Cengiz Ovalı; Mustafa Behçet Sevin
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-04-30       Impact factor: 0.332

3.  Which is the Optimal Frozen Elephant Trunk? A Systematic Review and Meta-Analysis of Outcomes in 2161 Patients Undergoing Thoracic Aortic Aneurysm Surgery Using E-vita OPEN PLUS Hybrid Stent Graft versus Thoraflex™ Hybrid Prosthesis.

Authors:  Amer Harky; Matthew Fok; Mohamad Bashir
Journal:  Braz J Cardiovasc Surg       Date:  2020-08-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.