Literature DB >> 18663635

Assessment of heart rate variability derived from finger-tip photoplethysmography as compared to electrocardiography.

N Selvaraj1, A Jaryal, J Santhosh, K K Deepak, S Anand.   

Abstract

Heart rate variability (HRV) is traditionally derived from RR interval time series of electrocardiography (ECG). Photoplethysmography (PPG) also reflects the cardiac rhythm since the mechanical activity of the heart is coupled to its electrical activity. Thus, theoretically, PPG can be used for determining the interval between successive heartbeats and heart rate variability. However, the PPG wave lags behind the ECG signal by the time required for transmission of pulse wave. In this study, finger-tip PPG and standard lead II ECG were recorded for five minutes from 10 healthy subjects at rest. The results showed a high correlation (median = 0.97) between the ECG-derived RR intervals and PPG-derived peak-to-peak (PP) intervals. PP variability was accurate (0.1 ms) as compared to RR variability. The time domain, frequency domain and Poincaré plot HRV parameters computed using RR interval method and PP interval method showed no significant differences (p < 0.05). The error analysis also showed insignificant differences between the HRV indices obtained by the two methods. Bland-Altman analysis showed high degree of agreement between the two methods for all the parameters of HRV. Thus, HRV can also be reliably estimated from the PPG based PP interval method.

Mesh:

Year:  2008        PMID: 18663635     DOI: 10.1080/03091900701781317

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  49 in total

1.  Monitoring of cardiovascular reactivity to cold stress using digital volume pulse characteristics in health and diabetes.

Authors:  Ashok K Jaryal; Nandakumar Selvaraj; Jayashree Santhosh; Sneh Anand; Kishore K Deepak
Journal:  J Clin Monit Comput       Date:  2009-03-24       Impact factor: 2.502

2.  Integrating fMRI with psychophysiological measurements in the study of decision-making.

Authors:  Savio W H Wong; Gui Xue; Antoine Bechara
Journal:  J Neurosci Psychol Econ       Date:  2011

3.  Monitoring of reactive hyperemia using photoplethysmographic pulse amplitude and transit time.

Authors:  Nandakumar Selvaraj; Ashok K Jaryal; Jayashree Santhosh; Sneh Anand; Kishore K Deepak
Journal:  J Clin Monit Comput       Date:  2009-10       Impact factor: 2.502

4.  Comparison of foot finding methods for deriving instantaneous pulse rates from photoplethysmographic signals.

Authors:  Mathilde C Hemon; Justin P Phillips
Journal:  J Clin Monit Comput       Date:  2015-04-24       Impact factor: 2.502

5.  Ambiguity of mapping the relative phase of blood pulsations.

Authors:  Victor Teplov; Ervin Nippolainen; Alexander A Makarenko; Rashid Giniatullin; Alexei A Kamshilin
Journal:  Biomed Opt Express       Date:  2014-08-22       Impact factor: 3.732

6.  Accurate measurement of the pulse wave delay with imaging photoplethysmography.

Authors:  Alexei A Kamshilin; Igor S Sidorov; Laura Babayan; Maxim A Volynsky; Rashid Giniatullin; Oleg V Mamontov
Journal:  Biomed Opt Express       Date:  2016-11-16       Impact factor: 3.732

7.  Heart rate variability characteristics in a large group of active-duty marines and relationship to posttraumatic stress.

Authors:  Arpi Minassian; Mark A Geyer; Dewleen G Baker; Caroline M Nievergelt; Daniel T O'Connor; Victoria B Risbrough
Journal:  Psychosom Med       Date:  2014-05       Impact factor: 4.312

8.  Autonomic function, voice, and mood states.

Authors:  Chan-Kyu Park; Sanghoon Lee; Hi-Joon Park; You-Sang Baik; Young-Bae Park; Young-Jae Park
Journal:  Clin Auton Res       Date:  2010-11-06       Impact factor: 4.435

9.  Toward Hypertension Prediction Based on PPG-Derived HRV Signals: a Feasibility Study.

Authors:  Kun-Chan Lan; Paweeya Raknim; Wei-Fong Kao; Jyh-How Huang
Journal:  J Med Syst       Date:  2018-04-21       Impact factor: 4.460

10.  Nonrigid Motion Correction With 3D Image-Based Navigators for Coronary MR Angiography.

Authors:  Jieying Luo; Nii Okai Addy; R Reeve Ingle; Corey A Baron; Joseph Y Cheng; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2016-05-13       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.