Literature DB >> 18663432

Acetylcholinesterase-based biosensors for quantification of carbofuran, carbaryl, methylparaoxon, and dichlorvos in 5% acetonitrile.

Gabriela Valdés-Ramírez1, Montserrat Cortina, Maria Teresa Ramírez-Silva, Jean-Louis Marty.   

Abstract

Amperometric acetylcholinesterase biosensors have been developed for quantification of the pesticides carbofuran, carbaryl, methylparaoxon, and dichlorvos in phosphate buffer containing 5% acetonitrile. Three different biosensors were built using three different acetylcholinesterase (AChE) enzymes-AChE from electric eel, and genetically engineered (B394) and wild-type (B1) AChE from Drosophila melanogaster. Enzymes were immobilized on cobalt(II) phthalocyanine-modified electrodes by entrapment in a photocrosslinkable polymer (PVA-AWP). Each biosensor was tested against the four pesticides. Good operational stability, immobilisation reproducibility, and storage stability were obtained for each biosensor. The best detection limits were obtained with the B394 enzyme for dichlorvos and methylparaoxon (9.6 x 10(-11) and 2.7 x 10(-9) mol L(-1), respectively), the B1 enzyme for carbofuran (4.5 x 10(-9) mol L(-1)), and both the B1 enzyme and the AChE from electric eel for carbaryl (1.6 x 10(-7) mol L(-1)). Finally, the biosensors were used for the direct detection of the pesticides in spiked apple samples.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18663432     DOI: 10.1007/s00216-008-2290-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  6 in total

Review 1.  Recent Advances in the Recognition Elements of Sensors to Detect Pyrethroids in Food: A Review.

Authors:  Le Zhang; Mingqi Zhao; Ming Xiao; Moo-Hyeog Im; A M Abd El-Aty; Hua Shao; Yongxin She
Journal:  Biosensors (Basel)       Date:  2022-06-10

2.  Esterases of Varroa destructor (Acari: Varroidae), parasitic mite of the honeybee.

Authors:  Małgorzata Dmitryjuk; Krystyna Żołtowska; Regina Frączek; Zbigniew Lipiński
Journal:  Exp Appl Acarol       Date:  2014-04       Impact factor: 2.132

Review 3.  Combining electrochemical sensors with miniaturized sample preparation for rapid detection in clinical samples.

Authors:  Natinan Bunyakul; Antje J Baeumner
Journal:  Sensors (Basel)       Date:  2014-12-30       Impact factor: 3.576

4.  Promising post-consumer PET-derived activated carbon electrode material for non-enzymatic electrochemical determination of carbofuran hydrolysate.

Authors:  Sureshkumar Ayyalusamy; Susmita Mishra; Vembu Suryanarayanan
Journal:  Sci Rep       Date:  2018-09-03       Impact factor: 4.379

Review 5.  Latest Trends in Electrochemical Sensors for Neurotransmitters: A Review.

Authors:  Zahra Tavakolian-Ardakani; Oana Hosu; Cecilia Cristea; Mohammad Mazloum-Ardakani; Giovanna Marrazza
Journal:  Sensors (Basel)       Date:  2019-04-30       Impact factor: 3.576

6.  A 3D printable adapter for solid-state fluorescence measurements: the case of an immobilized enzymatic bioreceptor for organophosphate pesticides detection.

Authors:  Andreia C M Rodrigues; Maria Vittoria Barbieri; Marco Chino; Giuseppe Manco; Ferdinando Febbraio
Journal:  Anal Bioanal Chem       Date:  2022-01-22       Impact factor: 4.142

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.