Literature DB >> 18663408

Multilumen central venous catheters increase risk for catheter-related bloodstream infection: prospective surveillance study.

A Templeton1, M Schlegel, F Fleisch, G Rettenmund, B Schöbi, S Henz, G Eich.   

Abstract

BACKGROUND: Catheter-related bloodstream infections (CRBSI) are a leading cause of nosocomial infections associated with significant mortality and costs. The objective of this study was to determine the rate of CRBSI in two large Swiss hospitals and to identify risk factors for this condition. PATIENTS AND METHODS: During 1 year all central venous catheter (CVC)-inserted in patients admitted for visceral, orthopedic or urologic surgery at the cantonal hospital in St Gallen and cantonal hospital in Chur were included in the study. Catheters were followed for the duration of their insertion. Blood cultures and semiquantitative cultures from catheters were drawn in the presence of local or systemic signs of infection. Primary endpoint was CRBSI defined as definite if (a) the same pathogen grew in at least one blood culture and from the distal segment of the catheter or (b) the same pathogen grew in at least one peripherally and centrally drawn blood culture and the differential time to positivity of central blood culture vs peripheral blood culture was > 120 min. CRBSI was defined as probable if at least one blood culture was positive with a recognized pathogen in the absence of another site of infection. Data were analyzed using univariate and multivariate time-to-event methods.
RESULTS: During the study period, 1,396 CVCs were prospectively studied in 1,162 patients. Incidence density of all CRBSIs (definite n = 29, probable n = 7) was 2.5 (95% CI: 1.8-3.5) per 1,000 catheter-days. The lowest rate of CRBSI was found in subclavian catheters, the adjusted hazard ratio (HR) for jugular catheters was 2.2 (95% CI: 1.1- 4.3; p = 0.03) and for femoral catheters 2.9 (95% CI: 0.6-14.4; p = 0.19). Each additional lumen increased the risk (HR = 4.4; 95% CI: 2.5-7.7; p < 0.001), whereas the permanent blocking of additional lumens was protective (HR = 0.3; 95% CI: 0.1-0.7; p = 0.006). The most commonly isolated organism were coagulase-negative staphylococci with a rate of 28%.
CONCLUSION: Number of lumens and site of access were independent risk factors for CRBSI. The use of catheters with multiple lumens should therefore be restricted as far as possible. If a catheter cannot be removed, the permanent closure of unneeded lumens may reduce the risk of CRBSI.

Entities:  

Mesh:

Year:  2008        PMID: 18663408     DOI: 10.1007/s15010-008-7314-x

Source DB:  PubMed          Journal:  Infection        ISSN: 0300-8126            Impact factor:   3.553


  12 in total

1.  A prospective 7-year survey on central venous catheter-related complications at a single pediatric hospital.

Authors:  M Pinon; S Bezzio; P A Tovo; F Fagioli; L Farinasso; R Calabrese; M Marengo; M Giacchino
Journal:  Eur J Pediatr       Date:  2009-03-17       Impact factor: 3.183

2.  Value of superficial cultures for prediction of catheter-related bloodstream infection in long-term catheters: a prospective study.

Authors:  M Guembe; P Martín-Rabadán; A Echenagusia; F Camúñez; G Rodríguez-Rosales; G Simó; M Echenagusia; E Bouza
Journal:  J Clin Microbiol       Date:  2013-07-12       Impact factor: 5.948

3.  Impact of postplacement adjustment of peripherally inserted central catheters on the risk of bloodstream infection and venous thrombus formation.

Authors:  Sanjiv M Baxi; Emily K Shuman; Christy A Scipione; Benrong Chen; Aditi Sharma; Jennifer J K Rasanathan; Carol E Chenoweth
Journal:  Infect Control Hosp Epidemiol       Date:  2013-06-18       Impact factor: 3.254

Review 4.  Prevention of Central Line-Associated Bloodstream Infections.

Authors:  Taison Bell; Naomi P O'Grady
Journal:  Infect Dis Clin North Am       Date:  2017-07-05       Impact factor: 5.982

Review 5.  Current Medical Treatment for Alcohol-Associated Liver Disease.

Authors:  Gustavo Ayares; Francisco Idalsoaga; Luis A Díaz; Jorge Arnold; Juan P Arab
Journal:  J Clin Exp Hepatol       Date:  2022-02-12

6.  Reduction of central line-associated bloodstream infections in a large acute care hospital in Midwest United States following implementation of a comprehensive central line insertion and maintenance bundle.

Authors:  Abraham E Wei; Ronald J Markert; Christopher Connelly; Hari Polenakovik
Journal:  J Infect Prev       Date:  2021-06-22

Review 7.  Strategies to prevent drug incompatibility during simultaneous multi-drug infusion in intensive care units: a literature review.

Authors:  Laura Négrier; Anthony Martin Mena; Gilles Lebuffe; Pascal Odou; Stéphanie Genay; Bertrand Décaudin
Journal:  Eur J Clin Pharmacol       Date:  2021-03-25       Impact factor: 2.953

8.  Success rate and complications of internal jugular vein catheterization with and without ultrasonography guide.

Authors:  Hamidreza Karimi-Sari; Mehrdad Faraji; Saman Mohazzab Torabi; Gholamreza Asjodi
Journal:  Nurs Midwifery Stud       Date:  2014-12-29

9.  Central line-related bloodstream infections and microbiological study in an Egyptian Ministry of Health Hospital.

Authors:  Khalil Shaaban Nahla; Ismaeel Sayed Manal; Mohamed Abdnaby Gehan
Journal:  Afr Health Sci       Date:  2020-03       Impact factor: 0.927

10.  Venue of catheter insertion does not significantly impact the event of central line-associated bloodstream infection in patients with haematological diseases.

Authors:  Hiroaki Kitamura; Yasushi Kubota; Sho Komukai; Hisako Yoshida; Yukari Kaneko; Yukiko Mihara; Zenzo Nagasawa; Atsushi Kawaguchi; Yosuke Aoki; Shinya Kimura
Journal:  Infect Prev Pract       Date:  2020-03-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.