| Literature DB >> 18661017 |
Carlos Antonio Rodrigues de Faria1, Fabio Akira Suzuki.
Abstract
UNLABELLED: The authors evaluated pure tone audiometry with and without specific ear protectors. AIM: The purpose of this case control study was to measure the level of sound attenuation by earplugs.Entities:
Mesh:
Year: 2008 PMID: 18661017 PMCID: PMC9442105 DOI: 10.1016/s1808-8694(15)30577-2
Source DB: PubMed Journal: Braz J Otorhinolaryngol ISSN: 1808-8686
Expected noise attenuation values provided by manufacturers for each frequency, in Hertz
| Frequency Hz | Attenuation (decibels) | Standard deviation |
|---|---|---|
| 500 | 31,0 | 6,0 |
| 1000 | 32,0 | 5,2 |
| 2000 | 36,4 | 5,2 |
| 4000 | 37,6 | 6,9 |
Summary of observed noise attenuation measurements (decibels) at each frequency.
| Frequency Hz | Mean | Standard deviation | Median | Mode | Minimum | Maximum |
|---|---|---|---|---|---|---|
| 500 | 22,8 | 3,8 | 25 | 20 | 15 | 35 |
| 1000 | 23,4 | 3,7 | 25 | 25 | 15 | 30 |
| 2000 | 27,3 | 4,5 | 27,5 | 30 | 20 | 35 |
| 4000 | 29,4 | 4,3 | 30 | 30 | 20 | 35 |
Chart 1Box-plot comparing noise attenuation at 500, 100, 2000 and 4000 Hertz.
Expected noise attenuation values provided by manufacturers for each frequency (in Hertz).
| Frequency Hz | Attenuation (decibels) | Standard deviation |
|---|---|---|
| 500 | 23,9 | 6,8 |
| 1000 | 23,5 | 5,9 |
| 2000 | 28,1 | 5,0 |
| 4000 | 29,2 | 6,9 |