Literature DB >> 18660557

Fluoroscopic gating without implanted fiducial markers for lung cancer radiotherapy based on support vector machines.

Ying Cui1, Jennifer G Dy, Brian Alexander, Steve B Jiang.   

Abstract

Various problems with the current state-of-the-art techniques for gated radiotherapy have prevented this new treatment modality from being widely implemented in clinical routine. These problems are caused mainly by applying various external respiratory surrogates. There might be large uncertainties in deriving the tumor position from external respiratory surrogates. While tracking implanted fiducial markers has sufficient accuracy, this procedure may not be widely accepted due to the risk of pneumothorax. Previously, we have developed a technique to generate gating signals from fluoroscopic images without implanted fiducial markers using template matching methods (Berbeco et al 2005 Phys. Med. Biol. 50 4481-90, Cui et al 2007b Phys. Med. Biol. 52 741-55). In this note, our main contribution is to provide a totally different new view of the gating problem by recasting it as a classification problem. Then, we solve this classification problem by a well-studied powerful classification method called a support vector machine (SVM). Note that the goal of an automated gating tool is to decide when to turn the beam ON or OFF. We treat ON and OFF as the two classes in our classification problem. We create our labeled training data during the patient setup session by utilizing the reference gating signal, manually determined by a radiation oncologist. We then pre-process these labeled training images and build our SVM prediction model. During treatment delivery, fluoroscopic images are continuously acquired, pre-processed and sent as an input to the SVM. Finally, our SVM model will output the predicted labels as gating signals. We test the proposed technique on five sequences of fluoroscopic images from five lung cancer patients against the reference gating signal as ground truth. We compare the performance of the SVM to our previous template matching method (Cui et al 2007b Phys. Med. Biol. 52 741-55). We find that the SVM is slightly more accurate on average (1-3%) than the template matching method, when delivering the target dose. And the average duty cycle is 4-6% longer. Given the very limited patient dataset, we cannot conclude that the SVM is more accurate and efficient than the template matching method. However, our preliminary results show that the SVM is a potentially precise and efficient algorithm for generating gating signals for radiotherapy. This work demonstrates that the gating problem can be considered as a classification problem and solved accordingly.

Entities:  

Mesh:

Year:  2008        PMID: 18660557     DOI: 10.1088/0031-9155/53/16/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Chitosan film containing poly(D,L-lactic-co-glycolic acid) nanoparticles: a platform for localized dual-drug release.

Authors:  Dayane B Tada; Surinder Singh; Dattatri Nagesha; Evan Jost; Craig O Levy; Evin Gultepe; Robert Cormack; G Mike Makrigiorgos; Srinivas Sridhar
Journal:  Pharm Res       Date:  2010-06-03       Impact factor: 4.200

2.  Use of dMLC for implementation of dynamic respiratory-gated radiation therapy.

Authors:  Eric W Pepin; Huanmei Wu; Hiroki Shirato
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

3.  Dynamic gating window for compensation of baseline shift in respiratory-gated radiation therapy.

Authors:  Eric W Pepin; Huanmei Wu; Hiroki Shirato
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

4.  Gating window dependency on scanned carbon-ion beam dose distribution and imaging dose for thoracoabdominal treatment.

Authors:  Shinichiro Mori; Masataka Karube; Shigeo Yasuda; Naoyoshi Yamamoto; Hiroshi Tsuji; Tadashi Kamada
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

5.  Marker-free lung tumor trajectory estimation from a cone beam CT sinogram.

Authors:  Geoffrey D Hugo; Jian Liang; Di Yan
Journal:  Phys Med Biol       Date:  2010-04-14       Impact factor: 3.609

6.  Evaluation of the accuracy and clinical practicality of a calculation system for patient positional displacement in carbon ion radiotherapy at five sites.

Authors:  Yoshiki Kubota; Hayato Hayashi; Satoshi Abe; Saki Souda; Ryosuke Okada; Takayoshi Ishii; Mutsumi Tashiro; Masami Torikoshi; Tatsuaki Kanai; Tatsuya Ohno; Takashi Nakano
Journal:  J Appl Clin Med Phys       Date:  2018-01-25       Impact factor: 2.102

7.  Delivery efficiency of an Elekta linac under gated operation.

Authors:  Guoqiang Cui; David J Housley; Fan Chen; Vivek K Mehta; David M Shepard
Journal:  J Appl Clin Med Phys       Date:  2014-09-08       Impact factor: 2.102

8.  A method of respiratory phase optimization for better dose sparing of organs at risks: A validation study in patients with lung cancer.

Authors:  Seong-Hee Kang; Siyong Kim; Dong-Su Kim; Tae-Ho Kim; So-Hyun Park; Dong-Seok Shin; Kyeong-Hyeon Kim; Min-Seok Cho; YeonSil Kim; Tae Suk Suh
Journal:  Oncotarget       Date:  2017-12-17
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.