Literature DB >> 18656755

Prospective outcomes of comminuted periarticular metacarpal and phalangeal fractures treated using a titanium plate system.

Shohei Omokawa1, Ryotaro Fujitani, Yoshihiro Dohi, Takumi Okawa, Hiroshi Yajima.   

Abstract

PURPOSE: The purpose of this study was to prospectively evaluate clinical results for open reduction and internal fixation of unstable metaphyseal fractures of the metacarpal and phalangeal bones using a miniature titanium plate.
METHODS: Fifty-one consecutive patients with periarticular fractures with metaphyseal comminution and displacement were enrolled. Intra-articular involvement with a split or depression fracture was identified in 22 hands. Minimum follow-up was 1 year. There were 37 male and 14 female patients; average age was 38 years (range, 14-63). Of the 51 fractures, 15 were open; 8 of these had additional soft tissue injury, involving neurovascular injury in 4 and extensor tendon injury in 6. The average duration from injury to surgery was 6 days (range, 2-40 days).
RESULTS: Bone union was successfully achieved in all patients over an average period of 2.6 months. The final range of total active motion (%TAM) was excellent (>85%) for 26, good (70%-84%) for 17, fair (50%-69%) for 5, and poor (<49%) for 3. Postoperative complications occurred in 5 patients, including fracture redisplacement in 2, a collapse or absorption of the condylar head in 2, and superficial infection due to hardware exposure in one. Subsequently, 2 of these patients had malrotation deformities or osteoarthritic changes in the injured finger. Plates were removed in 30 cases, and additional surgery was required in 20 cases. Postoperative grip strength averaged 87% of the contralateral side. Statistical analysis revealed that patient age was significantly correlated with %TAM of the injured finger at 1-year follow-up (p < .01), and intra-articular (p < .05) and phalangeal bone (p < .01) involvement, as well as associated soft tissue injury (p < .05), significantly affected the range of finger motion.
CONCLUSIONS: Despite the technical demands of plating for comminuted metacarpal and phalangeal fractures, the low-profile titanium plate system was highly effective in maintaining anatomic reduction. The postoperative complication rate was relatively low, and the objective outcomes approached a reasonable level at 1-year follow-up. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18656755     DOI: 10.1016/j.jhsa.2008.01.040

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  14 in total

1.  Delayed foreign-body reaction to absorbable implants in metacarpal fracture treatment.

Authors:  Panagiotis K Givissis; Stavros I Stavridis; Panayiotis J Papagelopoulos; Petros D Antonarakos; Anastasios G Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-05-15       Impact factor: 4.176

2.  Clinical Outcomes of Limited Open Intramedullary Headless Screw Fixation of Metacarpal Fractures in 91 Consecutive Patients.

Authors:  Gilad Eisenberg; Jason B Clain; Natanya Feinberg-Zadek; Matthew Leibman; Mark Belsky; David E Ruchelsman
Journal:  Hand (N Y)       Date:  2019-03-17

Review 3.  Metacarpal fractures: treatment and complications.

Authors:  Kathleen M Kollitz; Warren C Hammert; Nicholas B Vedder; Jerry I Huang
Journal:  Hand (N Y)       Date:  2014-03

4.  Percutaneous Distraction Pinning for Metacarpophalangeal Joint Stabilization After Blast or Crush Injuries of the Hand.

Authors:  Matthew A Langford; Kevin Cheung; Zhongyu Li
Journal:  Clin Orthop Relat Res       Date:  2015-09       Impact factor: 4.176

5.  Prospective Multicenter Randomized Controlled Trial Comparing Early Protected Movement and Splinting for Fifth Metacarpal Neck Fracture.

Authors:  Helene Retrouvey; Josephine Jakubowski; Mona Al-Taha; Anna Steve; Haley Augustine; Michael J Stein; Becher Al-Halabi; Johnny Ionut Efanov; Alexander Morzycki; David Tang; Martin LeBlanc; Paul Binhammer
Journal:  Plast Surg (Oakv)       Date:  2021-05-17       Impact factor: 0.947

6.  Comparison of AO Titanium Locking Plate and Screw Fixation versus Anterograde Intramedullary Fixation for Isolated Unstable Metacarpal and Phalangeal Fractures.

Authors:  Bing Zhang; Pan Hu; Kun-Lun Yu; Jiang-Bo Bai; De-Hu Tian; Gui-Sheng Zhang; Xin-Zhong Shao; Ying-Ze Zhang
Journal:  Orthop Surg       Date:  2016-08       Impact factor: 2.071

7.  Comparison of Clinical Outcomes of Phalangeal Fracture Treated with Dorsolateral Approach or Post-middle Approach Using AO Mini Titanium Plate.

Authors:  Guang Li; Shen Liu; Guoting Chen; Zengchun Li; Yangzhou Liu; Guixin Sun; Qingyou Lu; Xia Li; Jun Tan; Ming Guan
Journal:  Indian J Surg       Date:  2013-09-05       Impact factor: 0.656

Review 8.  [Metacarpophalangeal joint injuries and sequelae].

Authors:  R Meier
Journal:  Unfallchirurg       Date:  2014-04       Impact factor: 1.000

9.  Principles in the management of a mangled hand.

Authors:  Chong Ks Alphonsus
Journal:  Indian J Plast Surg       Date:  2011-05

10.  Long-Term Functional Results of Intra- and Extra-Articular Hand Fractures Treatment With Titanium Miniature Plates and Screws With Minimum Follow-Up of 24 Months.

Authors:  Sokratis Varitimidis; Zoe Dailiana; Dimitrios Agorastakis; Apostolos Fyllos; Aristeidis Zibis; Michael Hantes; Konstantinos Malizos
Journal:  Cureus       Date:  2021-06-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.