Literature DB >> 18656651

Indirect voltammetric determination of caffeine content in coffee using 1,4-benzoquinone modified carbon paste electrode.

Muluken Aklilu1, Merid Tessema, Mesfin Redi-Abshiro.   

Abstract

In this paper a simple and highly sensitive electroanalytical method for the determination of caffeine content using 1,4-benzoquinone modified carbon paste electrode is presented. The method is based on suppression of 1,4-benzoquinone peak current on addition of caffeine. Square-wave and cyclic voltammetric techniques were utilised for the investigation. The 1,4-benzoquinone modified electrode exhibited a well-defined peak with reproducible peak current values for repetitive measurements; and showed a decrease in peak current value with an increase in caffeine content. The result revealed two linear range regions between 0 mmol L(-1) and 0.5 mmol L(-1) and 0.5 mmol L(-1) and 8.0 mmol L(-1), with detection limits of 0.3 micromol L(-1) and 5.1 micromol L(-1), respectively. The method was then successfully applied to the determination of caffeine content in coffee samples. The effects of pH, electrode composition, step potential, pulse amplitude and square-wave frequency on the voltammetric responses were also investigated.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18656651     DOI: 10.1016/j.talanta.2008.04.042

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Characterization of local pH changes in brain using fast-scan cyclic voltammetry with carbon microelectrodes.

Authors:  Pavel Takmakov; Matthew K Zachek; Richard B Keithley; Elizabeth S Bucher; Gregory S McCarty; R Mark Wightman
Journal:  Anal Chem       Date:  2010-11-03       Impact factor: 6.986

2.  An electrochemical sensor for nanomolar detection of caffeine based on nicotinic acid hydrazide anchored on graphene oxide (NAHGO).

Authors:  Jemini Jose; Viswanathan Subramanian; Sadasivan Shaji; P B Sreeja
Journal:  Sci Rep       Date:  2021-06-03       Impact factor: 4.379

3.  Electro-oxidation mechanism and direct square-wave voltammetric determination of lidocaine with a carbon-paste electrode.

Authors:  Nadereh Rahbar; Zahra Ramezani; Ahmad Babapour
Journal:  Jundishapur J Nat Pharm Prod       Date:  2015-02-20

4.  Electrochemical Behaviour of Tinidazole at 1,4-Benzoquinone Modified Carbon Paste Electrode and Its Direct Determination in Pharmaceutical Tablets and Urine by Differential Pulse Voltammetry.

Authors:  Yosef Nikodimos; Beyene Hagos
Journal:  J Anal Methods Chem       Date:  2017-11-07       Impact factor: 2.193

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.