Literature DB >> 18656395

Alternative erasing times of the DenOptix system plate: performance on the detection of proximal caries.

Daniela P Melo1, Andrea A Pontual, Solange M Almeida, Paulo F Campos, Guilherme M Tosoni.   

Abstract

OBJECTIVE: Our aim was to investigate the DenOptix system for detection of proximal caries using alternative erasing times for the photostimulable phosphor plates. STUDY
DESIGN: Human teeth were X-rayed with phosphor plates using different erasing times. Five observers evaluated the images for the presence of caries by scoring the proximal surfaces of each tooth. Mean pixel intensity analyses were also carried out. The erasing times were evaluated using receiver operating characteristic (ROC) curve analysis. Analysis of variance for differences among erasing times and pixel intensity values was performed, followed by linear regression analysis for correlation between these variables.
RESULTS: The mean ROC curve for each erasing time varied from 0.61 to 0.66 (not significant). Analysis of variance did not show any significant effect of the erasing times on the pixel intensity values of the images (P > .05).
CONCLUSION: Erasing times for DenOptix phosphor plates from 20 to 130 s were satisfactory for diagnosis of proximal caries, and their use is therefore feasible in clinical practice.

Entities:  

Mesh:

Year:  2008        PMID: 18656395     DOI: 10.1016/j.tripleo.2008.04.033

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  4 in total

1.  The effect of delayed scanning of storage phosphor plates on occlusal caries detection.

Authors:  E Sogur; B G Baksi; A Mert
Journal:  Dentomaxillofac Radiol       Date:  2012-01-26       Impact factor: 2.419

2.  Effect of alternative photostimulable phosphor plates erasing times on subjective digital image quality.

Authors:  D P Melo; A Dos Anjos Pontual; S M de Almeida; P S F Campos; M C Alves; G M Tosoni
Journal:  Dentomaxillofac Radiol       Date:  2010-01       Impact factor: 2.419

3.  Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

Authors:  Daniela Pita De Melo; Adriana Dibo Cruz; Saulo Leonardo Sousa Melo; Julyanna Filgueiras GonçAlves De Farias; Francisco Haiter-Neto; Solange Maria De Almeida
Journal:  J Clin Diagn Res       Date:  2015-04-01

4.  Comparison of the delay in processing time and protective plastic cases in two phosphor plate systems.

Authors:  Ali Murat Aktan; Mehmet Ertuğrul Ciftçi; Faruk Akgünlü
Journal:  ScientificWorldJournal       Date:  2012-11-07