Literature DB >> 18652009

Intracardiac echocardiography in patients with pacing and defibrillating leads: a feasibility study.

Maria Grazia Bongiorni1, Andrea Di Cori, Ezio Soldati, Giulio Zucchelli, Giuseppe Arena, Luca Segreti, Raffaele De Lucia, Mario Marzilli.   

Abstract

BACKGROUND: Lead extraction, an important and necessary component of treatment for many common device and lead-related complications, is a procedure that can provoke much anxiety in even the most experienced operators given the potentially serious complications. The principal impediment to lead extraction is the body's response to an intravascular foreign body with matrix intravascular neoformation, which causes the lead to adhere to the endocardium or vascular structure, increasing the risk of vascular or myocardial damage with lead removal. Fluoroscopic visualization, the commonly visualization used tool, has several limits in terms of anatomical structures visualization. The aim of this study was to assess the safety and feasibility of intracardiac echocardiography (ICE) in patients undergoing pacing and defibrillating leads before and during a transvenous device removal, and its potential role in detecting intracardiac leads and areas of fibrous adherence.
METHODS: ICE interrogation was performed in 25 consecutive patients with pacing and defibrillating implantable cardioverter defibrillators (ICD) leads before and during device removal.
RESULTS: A programmed ICE analysis was completed in 23 out of 25 patients with excellent resolution, providing a "qualitative-quantitative" information on anatomical structures, cardiac leads, and related areas of fibrous adherence. No ICE-related complications occurred.
CONCLUSIONS: ICE evaluation is safe and feasible in patients with pacing and defibrillating leads before and during transvenous lead removal, offering an excellent visualization of cardiac leads and related areas of adherence. ICE can assist pacing and ICD lead removal and could improve procedure efficacy and safety.

Entities:  

Mesh:

Year:  2008        PMID: 18652009     DOI: 10.1111/j.1540-8175.2008.00656.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  6 in total

Review 1.  Current trends in the management of cardiac implantable electronic device (CIED) infections.

Authors:  Emanuele Durante-Mangoni; Irene Mattucci; Federica Agrusta; Marie-Françoise Tripodi; Riccardo Utili
Journal:  Intern Emerg Med       Date:  2012-06-29       Impact factor: 3.397

2.  Management of Cardiac Implantable Electronic Device Infection.

Authors:  Cristian Podoleanu; Jean-Claude Deharo
Journal:  Arrhythm Electrophysiol Rev       Date:  2014-11-29

3.  Superior vena cava echocardiography as a screening tool to predict cardiovascular implantable electronic device lead fibrosis.

Authors:  S Jeffrey Yakish; Arvin Narula; Robert Foley; Andrew Kohut; Steven Kutalek
Journal:  J Cardiovasc Ultrasound       Date:  2015-03-30

4.  Retrieval of a transcatheter pacemaker in sheep after a mid-term implantation time.

Authors:  Maria Grazia Bongiorni; Luca Segreti; Andrea Di Cori; Matthew Bonner; Michael Eggen; Pamela Omdahl
Journal:  HeartRhythm Case Rep       Date:  2015-10-23

5.  European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS).

Authors:  Carina Blomström-Lundqvist; Vassil Traykov; Paola Anna Erba; Haran Burri; Jens Cosedis Nielsen; Maria Grazia Bongiorni; Jeanne Poole; Giuseppe Boriani; Roberto Costa; Jean-Claude Deharo; Laurence M Epstein; Laszlo Saghy; Ulrika Snygg-Martin; Christoph Starck; Carlo Tascini; Neil Strathmore
Journal:  Europace       Date:  2020-04-01       Impact factor: 5.214

6.  Multiplane/3D transesophageal echocardiography monitoring to improve the safety and outcome of complex transvenous lead extractions.

Authors:  Mihai Strachinaru; Chris M Kievit; Sing C Yap; Alexander Hirsch; Marcel L Geleijnse; Tamas Szili-Torok
Journal:  Echocardiography       Date:  2019-03-24       Impact factor: 1.724

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.