Literature DB >> 18651646

Novel bioabsorbable salicylate-based polymer as a drug-eluting stent coating.

Refat Jabara1, Nicolas Chronos, Keith Robinson.   

Abstract

BACKGROUND: Permanent polymers used in current drug-eluting stents (DES) can trigger chronic inflammation and hypersensitivity reactions, which may contribute to the increased risk of late thrombosis and rebound restenosis. Therefore, optimal polymer selection and the use of completely absorbable but biocompatible polymers are expected to minimize these risks.
OBJECTIVES: We sought to evaluate a novel, potentially innately anti-inflammatory, bioabsorbable salicylate-based polymer as a DES coating, in a clinically relevant animal model.
METHODS: Four types of stents were implanted in pig coronary arteries using QCA to optimize stent apposition: bare metal stents (BMS); salicylic acid/adipic acid bioabsorbable polymer-only coated metal stents (SA/AA); biostable polymeric sirolimus-eluting stents (Cypher); and metal stents coated with salicylic acid/adipic acid bioabsorbable polymer containing sirolimus (SA/AA + S). The dose density of sirolimus was 8.3 microg/mm of stent length (similar to Cypher) with in vitro studies demonstrating elution over 30 days and complete polymer degradation in 37 days. Animals underwent angiographic restudy and were terminated at 1 month for complete histopathologic and histomorphometric analyses.
RESULTS: Both SA/AA + S and Cypher stents had significantly lower angiographic % stenosis when compared with BMS and SA/AA polymer-only groups (6 +/- 4% and 5 +/- 4% vs. 15 +/- 7% and 16 +/- 5%, respectively, P < 0.001). Intimal thickness was lower for SA/AA + S and Cypher than for BMS (0.14 +/- 0.06 and 0.13 +/- 0.04 mm vs. 0.23 +/- 0.05 mm, respectively, P < 0.001). Histologic % area stenosis was also lower for SA/AA + S and Cypher when compared with BMS (22 +/- 7% and 23 +/- 6% vs. 33 +/- 5%, respectively, P < 0.001). There was a strong trend toward reduced inflammatory response in the SA/AA and SA/AA + S when compared with BMS and Cypher groups (P = 0.072).
CONCLUSIONS: This study shows favorable vascular compatibility and efficacy for a novel bioabsorbable salicylate-based polymer as a DES coating, and supports further research and development of this unique class of polymer materials for applications in cardiovascular devices. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18651646     DOI: 10.1002/ccd.21607

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  15 in total

Review 1.  Bioresorbable Scaffolds: Current Evidences in the Treatment of Coronary Artery Disease.

Authors:  Bhargav Dave
Journal:  J Clin Diagn Res       Date:  2016-10-01

Review 2.  New generation bioresorbable scaffold technologies: an update on novel devices and clinical results.

Authors:  Damiano Regazzoli; Pier Pasquale Leone; Antonio Colombo; Azeem Latib
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

3.  Mechanical properties and in vivo performance of a novel sliding-lock bioabsorbable poly-p-dioxanone stent.

Authors:  Qimao Feng; Wenbo Jiang; Kun Sun; Kang Sun; Sun Chen; Lijiao Zhao; Ke Dai; Ning Ma
Journal:  J Mater Sci Mater Med       Date:  2011-08-06       Impact factor: 3.896

4.  Storage Stability Study of Salicylate-based Poly(anhydride-esters).

Authors:  Brittany M Deronde; Ashley L Carbone; Kathryn E Uhrich
Journal:  Polym Degrad Stab       Date:  2010-09-01       Impact factor: 5.030

Review 5.  New-Generation Coronary Stents: Current Data and Future Directions.

Authors:  Ankur Kalra; Hasan Rehman; Sahil Khera; Braghadheeswar Thyagarajan; Deepak L Bhatt; Neal S Kleiman; Robert W Yeh
Journal:  Curr Atheroscler Rep       Date:  2017-03       Impact factor: 5.113

6.  Design and Synthesis of Fast-Degrading Poly(anhydride-esters).

Authors:  Ashley L Carbone; Kathryn E Uhrich
Journal:  Macromol Rapid Commun       Date:  2009-06-17       Impact factor: 5.734

Review 7.  Bioresorbable scaffolds: current evidence and ongoing clinical trials.

Authors:  Christos V Bourantas; Yaojun Zhang; Vasim Farooq; Hector M Garcia-Garcia; Yoshinobu Onuma; Patrick W Serruys
Journal:  Curr Cardiol Rep       Date:  2012-10       Impact factor: 2.931

Review 8.  Absorbable stent: focus on clinical applications and benefits.

Authors:  Nieves Gonzalo; Carlos Macaya
Journal:  Vasc Health Risk Manag       Date:  2012-02-29

Review 9.  Bioresorbable scaffolds for percutaneous coronary interventions.

Authors:  Bill D Gogas
Journal:  Glob Cardiol Sci Pract       Date:  2014-12-31

10.  Bioresorbable scaffolds in the treatment of coronary artery disease.

Authors:  Yaojun Zhang; Christos V Bourantas; Vasim Farooq; Takashi Muramatsu; Roberto Diletti; Yoshinobu Onuma; Hector M Garcia-Garcia; Patrick W Serruys
Journal:  Med Devices (Auckl)       Date:  2013-03-12
View more