Literature DB >> 1865099

Infection control practices in gastrointestinal endoscopy in the United States: a national survey.

G J Gorse1, R L Messner.   

Abstract

OBJECTIVE: To ascertain current infection control practices, endoscope cleaning procedures, perceived risks of infection, and implementation of universal precautions in gastrointestinal endoscopy units in the United States.
DESIGN: National mailed survey of gastroenterology nurses and associates conducted anonymously in March 1988.
SETTING: Completed surveys were received from all 50 states and Puerto Rico and from all practice settings. The most common practice setting was private/community hospitals (66%). PARTICIPANTS: Of the 4,952 survey forms mailed to all members and to interested nonmembers of the Society of Gastrointestinal Nurses and Associates, 2,158 (44%) were returned and 2,030 (41%) were completed and evaluable. Of the respondents, 1,487 (73%) were registered nurses.
RESULTS: Sixty-seven percent (n = 1,358) of the respondents routinely used an enzymatic cleaner as a step in the instrument decontamination process; 93% (n = 1,879) chemically disinfected instruments after each case; and 88% (n = 1,779) disinfected endoscopes with an aqueous glutaraldehyde product. Respondents reported that they and a significantly smaller proportion of physicians (p less than .001) employed barrier precautions for all endoscopic cases involving possible contact with blood/body fluids of patients known (66% versus 57%, respectively) and not known (12% versus 8%, respectively) to have a bloodborne infection. Endoscopy-related infections, usually bacterial, were reported to have occurred at their institutions by 6% (n = 116) of respondents.
CONCLUSIONS: We conclude that cleaning, disinfection, and sterilization procedures for gastrointestinal endoscopic instruments vary, that appropriate protective apparel is not always worn, and that some practices may lead to preventable endoscopy-related infection in patients.

Entities:  

Mesh:

Year:  1991        PMID: 1865099     DOI: 10.1086/646341

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  11 in total

1.  Epidemiology and Prevention of Infections Related to Endoscopy.

Authors:  Arjun Srinivasan
Journal:  Curr Infect Dis Rep       Date:  2003-12       Impact factor: 3.725

2.  Current GI endoscope disinfection and QA practices.

Authors:  Frank M Moses; Jennifer S Lee
Journal:  Dig Dis Sci       Date:  2004 Nov-Dec       Impact factor: 3.199

Review 3.  Current issues in endoscope reprocessing and infection control during gastrointestinal endoscopy.

Authors:  Douglas B Nelson; Lawrence F Muscarella
Journal:  World J Gastroenterol       Date:  2006-07-07       Impact factor: 5.742

4.  Cost comparison of reusable and single-use ultrasonic shears for laparoscopic bariatric surgery.

Authors:  Elliot Yung; Michel Gagner; Alfons Pomp; Gregory Dakin; Luca Milone; Gladys Strain
Journal:  Obes Surg       Date:  2008-11-18       Impact factor: 4.129

Review 5.  Superbugs on Duodenoscopes: the Challenge of Cleaning and Disinfection of Reusable Devices.

Authors:  Romney M Humphries; Gerald McDonnell
Journal:  J Clin Microbiol       Date:  2015-07-22       Impact factor: 5.948

6.  Precautionary practices of healthcare workers who disinfect medical and dental devices using high-level disinfectants.

Authors:  Scott A Henn; James M Boiano; Andrea L Steege
Journal:  Infect Control Hosp Epidemiol       Date:  2015-02       Impact factor: 3.254

7.  High seroprevalence of IgG against Helicobacter pylori among endoscopists in Taiwan.

Authors:  Y C Su; W M Wang; L T Chen; W Chiang; C Y Chen; S N Lu; C M Jan
Journal:  Dig Dis Sci       Date:  1996-08       Impact factor: 3.199

Review 8.  Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy.

Authors:  Julia Kovaleva; Frans T M Peters; Henny C van der Mei; John E Degener
Journal:  Clin Microbiol Rev       Date:  2013-04       Impact factor: 26.132

9.  Bactericidal, virucidal, and mycobactericidal activities of reused alkaline glutaraldehyde in an endoscopy unit.

Authors:  J N Mbithi; V S Springthorpe; S A Sattar; M Pacquette
Journal:  J Clin Microbiol       Date:  1993-11       Impact factor: 5.948

10.  Recent update of gastrointestinal endoscope reprocessing.

Authors:  Kyong Hee Hong; Yun Jeong Lim
Journal:  Clin Endosc       Date:  2013-05-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.