Literature DB >> 18648260

Biliary tract depiction in living potential liver donors at 3.0-T magnetic resonance cholangiography.

So Yeon Kim1, Jae Ho Byun, Hye-Suk Hong, Eugene K Choi, Seung Soo Lee, Seong Ho Park, Moon-Gyu Lee.   

Abstract

OBJECTIVES: To prospectively evaluate accuracy of biliary anatomy depiction and quality of biliary tract visualization of magnetic resonance cholangiography (MRC) at 3.0 T in living potential liver donors (LPLDs).
MATERIALS AND METHODS: Our institutional review board approved this study and did not require patient's informed consent. Thirty-three LPLDs underwent MRC at 3.0-T magnetic resonance and intraoperative cholangiography as the reference standard. MRC protocol included breath-hold rapid acquisition with relaxation enhancement (RARE) and respiratory-triggered 3-dimensional turbo spin-echo (TSE) T2-weighted sequence. Two readers independently analyzed 2 MRC image sets with a 2-week interval for delineating biliary anatomy and scoring degree of visualization of biliary branches with a 4-point scale, and recorded the number of visible third-order branches. One month later, both readers independently evaluated combined both MRC image set to assess biliary anatomy.
RESULTS: Biliary anatomy was correctly depicted by RARE sequence in 28 (84.8%) and 26 LPLDs (78.8%), by TSE sequence in 27 (81.8%) and 26 (78.8%), and by combined both sequences in 27 (81.8%) and 28 (84.8%), for readers 1 and 2, respectively. The mean second-order branch visualization scores for 2 readers were significantly higher for RARE images than for TSE (2.23 vs. 1.68, P = 0.02; 2.05 vs. 1.54, P = 0.02, respectively). The mean numbers of visible third-order branches were significantly higher for RARE images than TSE for both readers (4.36 vs. 3.04, P = 0.03; 4.72 vs. 3.32, P = 0.03, respectively).
CONCLUSIONS: In LPLDs, MRC at 3.0 T with both RARE and TSE sequences enables accurate depiction of biliary anatomy. RARE sequence more clearly visualizes second- and third-order biliary branches than TSE sequence.

Entities:  

Mesh:

Year:  2008        PMID: 18648260     DOI: 10.1097/RLI.0b013e31817e9b52

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  2 in total

1.  Anatomic variations of intrahepatic bile ducts in a European series and meta-analysis of the literature.

Authors:  Alessandro Cucchetti; Eugenia Peri; Matteo Cescon; Matteo Zanello; Giorgio Ercolani; Chiara Zanfi; Valentina Bertuzzo; Paolo Di Gioia; Antonio Daniele Pinna
Journal:  J Gastrointest Surg       Date:  2011-02-12       Impact factor: 3.452

2.  Biliary and vascular anomalies in living liver donors: the role and accuracy of pre-operative radiological mapping.

Authors:  Maja Segedi; Andrzej K Buczkowski; Charles H Scudamore; Eric M Yoshida; Alison C Harris; Kristin DeGirolamo; Stephen W Chung
Journal:  HPB (Oxford)       Date:  2013-02-01       Impact factor: 3.647

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.