[Contrast enhancement technique in brain 3D-CTA studies: optimizing the amount of contrast medium according to scan time based on TDC].

Kazuaki Terasawa1, Atsushi Hatcho.   

Abstract

In three-dimensional CT angiography (3D-CTA), good reproducibility can be obtained by maintaining the maximum CT numbers (HU) at a specified level. However, the correlation between the scan time and the injection time showed that the maximum CT numbers increased and varied due to the additional contrast enhancement effect from recirculation of the injected contrast medium for longer injection times when the dose of iodinated contrast medium per unit time (mgI/s) was maintained at a specified level based on the time-density curve (TDC) of the phantom. The amount of contrast medium employed at our hospital has been optimized based on an iodinated contrast medium dose per unit time providing a contrast enhancement effect of 300 HU in the middle cerebral artery. Using this standard, a TDC phantom was employed to obtain an iodinated contrast medium dose per unit time, permitting equivalent maximum CT values (used as standard values) to be obtained by changing the injection time. A contrast-enhancement technique that accounts for the variation in the scan time was evaluated. Strong correlations were observed between the scan time and the injection time (R2=0.969) and between the injection time and the dose of iodinated contrast medium per unit body weight (R2=0.994). We conclude that adjusting the dose of iodinated contrast medium per unit body weight per unit time according to the scan time permits optimization of the contrast-enhancement technique.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18648157     DOI: 10.6009/jjrt.64.681

Source DB:  PubMed          Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi        ISSN: 0369-4305


  3 in total

1.  A new method with variable injection parameters in contrast-enhanced CT: a phantom study for evaluating an aortic peak enhancement.

Authors:  Kazuaki Terasawa; Atsunori Maruyama; Tomohiro Tsukimata
Journal:  Radiol Phys Technol       Date:  2015-05-01

2.  Evaluation of ITA Graft Function Using CT Angiography.

Authors:  Makoto Hashimoto; Akihiko Yamauchi; Shuichi Naraoka; Satomi Inoue; Tetsuya Higami
Journal:  Ann Vasc Dis       Date:  2012

3.  Verification of the Dose Reduction Effect via Diluted Injection in Dual-Energy Computed Tomography Using a Human Blood Flow Phantom.

Authors:  Hironobu Tomita; Koichi Shibata
Journal:  Radiol Res Pract       Date:  2019-04-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.