Literature DB >> 18645428

Smooth nylon foil (SupraFOIL) orbital implants in orbital fractures: a case series of 181 patients.

D J John Park1, Daniel C Garibaldi, Nicholas T Iliff, Michael P Grant, Shannath L Merbs.   

Abstract

PURPOSE: The SupraFOIL smooth nylon foil implant is a polyamide sheet available in varying thicknesses that has been used in orbital reconstruction following trauma. The authors report their experience with smooth nylon foil implants in the repair of orbital fractures.
METHODS: A retrospective chart review of patients having undergone repair of orbital fractures between January 1, 1995 and December 31, 2003 was conducted. The Wilcoxon test was used to compare cases with complications and those with no complications.
RESULTS: Of 282 orbits that underwent fracture repair with alloplastic material, 87 were excluded because non-nylon foil implants were used alone or in combination with nylon foil to repair the orbital fracture. An additional 14 fractures were excluded because of insufficient clinical data or lack of follow-up, for a total of 181 orbits that underwent orbital fracture repair with only nylon foil. A transconjunctival approach was used in 98% cases, and all 181 implants were fixated with at least 1 titanium screw. Average follow-up was 362.8 days. The overall complication rate was 1.7%. One patient had an acute postoperative orbital hemorrhage (0.6% acute complication rate). Two patients had late orbital infections, 683 days and 984 days following repair (1.1% late complication rate).
CONCLUSIONS: The authors found the smooth nylon foil implant to be safe and effective in orbital fracture repair. The lower rate of complications the authors observed compared with previously reported series may be related to implant fixation. A titanium screw secured just posterior to the orbital rim may decrease long-term complications by providing more stability than implants left without fixation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18645428     DOI: 10.1097/IOP.0b013e31817e0fe0

Source DB:  PubMed          Journal:  Ophthalmic Plast Reconstr Surg        ISSN: 0740-9303            Impact factor:   1.746


  6 in total

1.  Secondary infection affecting one of two simultaneously placed orbital wall implants.

Authors:  Sonya Babar; Nicholas T Iliff; Emily Macquaid
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2009-05

Review 2.  Orbital Fracture Repair.

Authors:  Seanna Grob; Marc Yonkers; Jeremiah Tao
Journal:  Semin Plast Surg       Date:  2017-02       Impact factor: 2.314

Review 3.  Virtual Surgical Planning for Orbital Reconstruction.

Authors:  Srinivas M Susarla; Katherine Duncan; Nicholas R Mahoney; Shannath L Merbs; Michael P Grant
Journal:  Middle East Afr J Ophthalmol       Date:  2015 Oct-Dec

4.  Reconstruction of Medial Wall Blowout Fracture Defect with a Combination of Resorbable Meshed Plate and Cancellous Bone Allograft.

Authors:  Jongweon Shin; Song I Park; Yunsup Hwang; Ho Kwon; Hyung-Sup Shim
Journal:  Biomed Res Int       Date:  2019-10-15       Impact factor: 3.411

5.  Repair of unilateral combined orbital floor and medial wall fracture using two titanium mesh plates: a modified technique.

Authors:  Jinguo Yu; Jingkai Zhang; Song Chen; Qi Han; Hua Yan
Journal:  Ann Transl Med       Date:  2021-03

6.  Delayed Management of an Orbital Floor Blow-out Fracture.

Authors:  Aida Pidro; Nina Jovanovic; Emina Kadribašic; Nedim Barucija; Nedim Leto; Alon Kahana
Journal:  Beyoglu Eye J       Date:  2021-09-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.