Literature DB >> 18644603

Ultra-pressure liquid chromatography-electrospray tandem mass spectrometry for multiresidue determination of pesticides in water.

G Gervais1, S Brosillon, A Laplanche, C Helen.   

Abstract

A multiresidue analysis method has been developed for the determination of pesticides in water by ultra-performance liquid chromatography (UPLC) combined with tandem mass spectrometry (MS/MS). The selected pesticides represent a broad range of polarity and volatility [benzoylcyclohexanedione (mesotrione and sulcotrione); chloroacetamide (acetochlor, alachlor, dimethenamide, and metolachlor); phenoxyacetic acid (2,4-D and MCPA); phenoxypropionic (dichloprop and mecoprop); phenylurea (chlortoluron, diuron, isoproturon, linuron, and metoxuron); sulfonylurea (foramsulfuron, iodosulfuron, and nicolsulfuron); triazine (atrazine, cyanazine, desethylatrazine (DEA), desisopropylatrazine (DIA), simazine, and terbutylazine)]. The analytes were extracted using solid-phase extraction (SPE). The separation was carried out on an acquity UPLC BEH C18 column (1.7 microm, 50 mm x 1 mm ID) using a gradient elution profile and mobile phase consisting of 0.1% formic acid in water and acetonitrile. The pesticides were detected with a tandem mass spectrometer after being ionised positively or negatively (depending on the molecule) using an electrospray ionisation (ESI) source. To achieve the suitable extraction conditions for sample preparation, several parameters affecting the efficiency of SPE such as the nature of the sorbent and the eluent, extractant volume and pH were studied. The best recovery was obtained by the extraction with an Oasis HLB cartridge and 3 mL of a solution of acetonitrile/dichloromethane (1:1, v/v) at pH 2. The average recoveries of the pesticides in different samples ranged from 82 to 109%. The weight least squares (WLS) linear regression was used to calculate the limits of detection and quantification (LOD and LOQ) because the dispersion was heteroskedastic. All the pesticides could be correctly quantified at a concentration level of 50 ng L(-1) and most of them could be detected at a concentration inferior or equal to 8 ng L(-1). Efficiency and robustness of this method were evaluated by the analysis of several samples of real natural water.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18644603     DOI: 10.1016/j.chroma.2008.07.006

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  10 in total

1.  New indexes for compound prioritization and complexity quantification on environmental monitoring inventories.

Authors:  Antoni Ginebreda; Aleksandra Jelić; Mira Petrović; Miren López de Alda; Damià Barceló
Journal:  Environ Sci Pollut Res Int       Date:  2011-07-07       Impact factor: 4.223

2.  Uptake of microcontaminants by crops irrigated with reclaimed water and groundwater under real field greenhouse conditions.

Authors:  Diana Calderón-Preciado; Víctor Matamoros; Robert Savé; Pere Muñoz; Carme Biel; J M Bayona
Journal:  Environ Sci Pollut Res Int       Date:  2013-02-09       Impact factor: 4.223

3.  Dissipation and residue of MCPA (4-chloro-2-ethylphenoxyacetate) in wheat and soil.

Authors:  Jiye Hu; Tao Yang; Shaoyin Yin; Di Cao
Journal:  Environ Monit Assess       Date:  2011-09-14       Impact factor: 2.513

4.  New procedures for simultaneous determination of mesotrione and atrazine in water and soil. Comparison of the degradation processes of mesotrione and atrazine.

Authors:  Hanna Barchanska; Małgorzata Rusek; Anna Szatkowska
Journal:  Environ Monit Assess       Date:  2011-03-18       Impact factor: 2.513

5.  Reliable methods for determination of triazine herbicides and their degradation products in seawater and marine sediments using liquid chromatography-tandem mass spectrometry.

Authors:  N Rodríguez-González; R Uzal-Varela; M J González-Castro; S Muniategui-Lorenzo; E Beceiro-González
Journal:  Environ Sci Pollut Res Int       Date:  2017-01-27       Impact factor: 4.223

6.  HKUST-1 metal-organic framework for dispersive solid phase extraction of 2-methyl-4-chlorophenoxyacetic acid (MCPA) prior to its determination by ion mobility spectrometry.

Authors:  Masoumeh Mohammadnejad; Zahra Gudarzi; Shokoofeh Geranmayeh; Vahideh Mahdavi
Journal:  Mikrochim Acta       Date:  2018-10-04       Impact factor: 5.833

7.  Evaluation of the QuEChERS method and gas chromatography-mass spectrometry for the analysis pesticide residues in water and sediment.

Authors:  S H G Brondi; A N de Macedo; G H L Vicente; A R A Nogueira
Journal:  Bull Environ Contam Toxicol       Date:  2010-12-17       Impact factor: 2.151

8.  Fluorescence spectroscopy approaches for the development of a real-time organophosphate detection system using an enzymatic sensor.

Authors:  Paola Carullo; Giovanni Paolo Cetrangolo; Luigi Mandrich; Giuseppe Manco; Ferdinando Febbraio
Journal:  Sensors (Basel)       Date:  2015-02-09       Impact factor: 3.576

9.  Determination and occurrence of phenoxyacetic acid herbicides and their transformation products in groundwater using ultra high performance liquid chromatography coupled to tandem mass spectrometry.

Authors:  Sarah-Louise McManus; Mary Moloney; Karl G Richards; Catherine E Coxon; Martin Danaher
Journal:  Molecules       Date:  2014-12-10       Impact factor: 4.411

10.  Determination of Picomolar Concentrations of Paraoxon in Human Urine by Fluorescence-Based Enzymatic Assay.

Authors:  Giovanni Paolo Cetrangolo; Carla Gori; Janis Rusko; Sara Terreri; Giuseppe Manco; Amelia Cimmino; Ferdinando Febbraio
Journal:  Sensors (Basel)       Date:  2019-11-07       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.