Literature DB >> 18639416

Basic fibroblast growth factor slow release stent graft for endovascular aortic aneurysm repair: a canine model experiment.

Masaki Kajimoto1, Takatsugu Shimono, Koji Hirano, Yoichiro Miyake, Noriyuki Kato, Kyoko Imanaka-Yoshida, Hideto Shimpo, Keiichi Miyamoto.   

Abstract

OBJECTIVE: Persistent endoleak and endotension, complications after endovascular aortic repair, may be caused by an unorganized thrombus inside the aneurysm. The experimental study was designed to evaluate the effectiveness of stent grafts (S/Gs) with slow release of basic fibroblast growth factor (bFGF) for the organization.
METHODS: The S/Gs were constructed of self-expanding Z stent covered with expanded polytetra fluoroethylene graft, and coated with elastin to be able to bind and slowly release bFGF. Five elastin-coated S/Gs with bFGF (bFGF-S/Gs) and without bFGF (C-S/Gs) were placed in the normal canine aorta respectively. The thoracic aortic aneurysm models were surgically created with a jugular vein patch in 12 beagles. S/Gs with six holes, for creating endoleaks, were used in the experiment of aneurysmal repair. The bFGF-S/Gs (n = 6) and C-S/Gs (n = 6) were implanted. The beagles were sacrificed at two weeks after the endovascular procedure and examined histologically.
RESULTS: The bFGF-S/Gs induced six times the intimal proliferation of the C-S/Gs in normal aorta. Twelve animals had successfully created aneurysms, and had endoleaks just after the endovascular procedure. At two weeks after the endovascular procedure, the percentage of fibrous area in the aneurysmal cavity treated with bFGF-S/G (35.7 +/- 4.3%) was significantly greater than C-S/G (13.6 +/- 2.2%) (P < .01).
CONCLUSION: bFGF-S/Gs are effective for accelerating organization of the aneurysm cavity and developing neointima. Further research on bFGF-S/Gs would clarify the association of endoleaks.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18639416     DOI: 10.1016/j.jvs.2008.05.060

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  2 in total

1.  Implantation study of a tissue-engineered self-expanding aortic stent graft (bio stent graft) in a beagle model.

Authors:  Hidetake Kawajiri; Takeshi Mizuno; Takeshi Moriwaki; Ryosuke Iwai; Hatsue Ishibashi-Ueda; Masashi Yamanami; Keiichi Kanda; Hitoshi Yaku; Yasuhide Nakayama
Journal:  J Artif Organs       Date:  2014-10-16       Impact factor: 1.731

2.  Basic fibroblast growth factor gene transfection in repair of internal carotid artery aneurysm wall.

Authors:  Lei Jiao; Ming Jiang; Jinghai Fang; Yinsheng Deng; Zejun Chen; Min Wu
Journal:  Neural Regen Res       Date:  2012-12-25       Impact factor: 5.135

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.