Literature DB >> 18638586

Usefulness of microvolt T-wave alternans to predict outcomes in patients with ischemic cardiomyopathy beyond one year.

Paul S Chan1, Dean J Kereiakes, Cheryl Bartone, Theodore Chow.   

Abstract

Previous studies have demonstrated that microvolt T-wave alternans (MTWA) screening effectively risk-stratifies patients with ischemic cardiomyopathy. Whether the prognostic utility of MTWA diminishes over 3 years of follow-up remains unknown. In this study, a prospective cohort of 768 patients with ischemic cardiomyopathy (left ventricular ejection fraction <35%) and no previous sustained ventricular arrhythmia was developed, of whom 514 (67%) screened MTWA nonnegative (positive and indeterminate). The mean follow-up period was 18 +/- 11 months. The primary end point was all-cause mortality and appropriate implantable cardioverter-defibrillator shocks. Stratified Cox regression analyses (by implantable cardioverter-defibrillator status) estimated the predictive power of MTWA within each year of follow-up and determined whether this diminished over time. There were 99 deaths (MTWA negative: 21 [8.3%]; MTWA nonnegative: 78 [15.2%]) and 33 appropriate implantable cardioverter-defibrillator shocks (MTWA negative: 3 [4.0%]; MTWA nonnegative: 30 [9.5%]). After multivariate adjustment, a nonnegative MTWA test result was associated with a greater than twofold increased risk for events in each of the 3 years of follow-up (year 1: stratified hazard ratio 2.19, 95% confidence interval 1.10 to 4.34, p = 0.03; year 2: stratified hazard ratio 3.36, 95% confidence interval 1.28 to 8.83, p = 0.01; year 3: stratified hazard ratio 2.06, 95% confidence interval 0.81 to 5.22, p = 0.13). There were no significant interactions between the time periods (year 1 vs year 2: p = 0.47; year 1 vs year 3: p = 0.92). In conclusion, MTWA reliably and consistently predicts mortality and arrhythmic risk throughout the first 2 to 3 years of follow-up. Although these findings need further validation, they suggest that rescreening with MTWA may not need to be performed more frequently than once every 2 years.

Entities:  

Mesh:

Year:  2008        PMID: 18638586     DOI: 10.1016/j.amjcard.2008.03.049

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  6 in total

1.  T-wave alternans and ventricular arrhythmias in athletes: usefulness of follow-up updates.

Authors:  Giuseppe Inama; Claudio Pedrinazzi
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-01       Impact factor: 1.468

Review 2.  Sudden cardiac death risk stratification.

Authors:  Marc W Deyell; Andrew D Krahn; Jeffrey J Goldberger
Journal:  Circ Res       Date:  2015-06-05       Impact factor: 17.367

3.  The year of 2008 in electrocardiology.

Authors:  Shlomo Stern
Journal:  Ann Noninvasive Electrocardiol       Date:  2010-01       Impact factor: 1.468

Review 4.  Microvolt T-wave alternans physiological basis, methods of measurement, and clinical utility--consensus guideline by International Society for Holter and Noninvasive Electrocardiology.

Authors:  Richard L Verrier; Thomas Klingenheben; Marek Malik; Nabil El-Sherif; Derek V Exner; Stefan H Hohnloser; Takanori Ikeda; Juan Pablo Martínez; Sanjiv M Narayan; Tuomo Nieminen; David S Rosenbaum
Journal:  J Am Coll Cardiol       Date:  2011-09-20       Impact factor: 24.094

5.  [Microvolt T-wave alternans. Ischemic vs. nonischemic dilated cardiomyopathy].

Authors:  Thomas Klingenheben
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2015-02-19

6.  Hemodynamic consequences of severe lactic acidosis in shock states: from bench to bedside.

Authors:  Antoine Kimmoun; Emmanuel Novy; Thomas Auchet; Nicolas Ducrocq; Bruno Levy
Journal:  Crit Care       Date:  2015-04-09       Impact factor: 9.097

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.