BAHA devices and magnetic resonance imaging scanners.

Michael H Fritsch1, Ilka C Naumann, Kristine M Mosier.   

Abstract

HYPOTHESIS: That an osteointegrated Bone-anchored Hearing Aid (BAHA System) will show movement or displacement when exposed to a 9.4-T magnetic resonance imaging (MRI) magnet and that any movement may have implications for patient safety and image quality.
BACKGROUND: BAHA System implanted patients may require MRI scans for various pathologies. The possibility of BAHA fixture and abutment movement can be explored to help clarify patients' and physicians' decisions regarding safety issues.
SETTING: University Medical Center (tertiary care center).
METHODS: BAHA System assembled fixture with abutment of 3 and 4 mm were each placed inside of a Petri dish and mounted into human cadaver temporal bones, then exposed to a 9.4-T MRI magnet. The BAHA System external processor was entered into the MRI suite. Head MRI images and charts of 2 patients with BAHA System devices who had undergone MRI scanning at 1.5 and 3.0 T, respectively, were reviewed.
RESULTS: The BAHA System fixture with abutment moved inside of the Petri dish. The temporal bone studies revealed no sign of motion or displacement. The external BAHA processor showed strong movement toward the magnet. MRI scannings of patients were without any adverse effects. Image MRI quality was affected only around the BAHA post.
CONCLUSION: The bone-mounted fixture with abutment of 3 and 4 mm resisted any magnetic forces trying to displace them up to 9.4 T. Two patients underwent scanning at 1.5 and 3.0 T with no adverse effects. MRI image quality was excellent starting at 1 cm from the fixture with abutment. The study findings lend strong evidence that patients can be safely scanned up to 9.4 T without adverse effects.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18636027     DOI: 10.1097/MAO.0b013e31818201fd

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  6 in total

1.  Bone Conduction Implants for Hearing Rehabilitation in Skull Base Tumor Patients.

Authors:  Lauren Placke; Eric N Appelbaum; Akash J Patel; Alex D Sweeney
Journal:  J Neurol Surg B Skull Base       Date:  2019-02-06

Review 2.  Middle ear implantable hearing devices: an overview.

Authors:  David S Haynes; Jadrien A Young; George B Wanna; Michael E Glasscock
Journal:  Trends Amplif       Date:  2009-09

Review 3.  Diseases of the middle ear in childhood.

Authors:  Amir Minovi; Stefan Dazert
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2014-12-01

Review 4.  Safety of active auditory implants in magnetic resonance imaging.

Authors:  Guy Fierens; Nina Standaert; Ronald Peeters; Christ Glorieux; Nicolas Verhaert
Journal:  J Otol       Date:  2021-01-06

5.  Magnetic resonance imaging investigation of the bone conduction implant - a pilot study at 1.5 Tesla.

Authors:  Karl-Johan Fredén Jansson; Bo Håkansson; Sabine Reinfeldt; Cristina Rigato; Måns Eeg-Olofsson
Journal:  Med Devices (Auckl)       Date:  2015-10-23

6.  Comment on "Original Solution for Middle Ear Implant and Anesthetic/Surgical Management in a Child with Severe Craniofacial Dysmorphism".

Authors:  Ivo Joachim Kruyt; Ann-Louise Mc Dermott; Myrthe Karianne Sophie Hol
Journal:  Case Rep Otolaryngol       Date:  2016-07-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.