Literature DB >> 18631275

Mapping of intraatrial reentrant tachycardias by remote magnetic navigation in patients with d-transposition of the great arteries after mustard or senning procedure.

Jinjin Wu1, Andreas Pflaumer, Isabel Deisenhofer, Ekrem Ucer, John Hess, Bernhard Zrenner, Gabriele Hessling.   

Abstract

UNLABELLED: Remote Magnetic Mapping After Mustard/Senning Procedure.
INTRODUCTION: Mapping of intraatrial reentrant tachycardia (IART) still presents a challenge in complex congenital heart disease. The goal of this work was to present our initial experience with remote magnetic navigation (RMN) for mapping of IART in four patients after the atrial switch procedure (Mustard n = 1, Senning n = 3) for d-transposition of the great arteries.
METHODS: Three-dimensional (3D) mapping of the systemic venous atrium and the pulmonary venous atrium (PVA) was performed using RMN (Niobe) in conjunction with 3D mapping (CartoRMT). The maps were fused with a CT-based 3D anatomy.
RESULTS: All patients had cavotricuspid isthmus-dependent IART with a mean atrial cycle length of 305 ms. Mapping of both atria (PVA retrogradely by passing the aortic and tricuspid valve) was feasible and safe. The procedure time for IART mapping ranged from 210 to 320 minutes with a mean of 251 minutes. The fluoroscopy time for IART mapping ranged from 15.8 to 45.0 minutes (mean 31.6 minutes) for patients, and ranged from 12.3 to 24.3 minutes with a mean of 19.5 minutes for physicians. No procedural complications occurred.
CONCLUSION: Precise mapping of IART in the complex anatomical structures after an atrial switch procedure was feasible and safe using RMN. The maneuverability of the catheter was possible even with a retrograde access crossing two valves. Further reduction of procedural and fluoroscopy times for both patients and physicians seems possible.

Entities:  

Mesh:

Year:  2008        PMID: 18631275     DOI: 10.1111/j.1540-8167.2008.01231.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  5 in total

1.  Forces on cardiac implantable electronic devices during remote magnetic navigation.

Authors:  C Jilek; C Lennerz; B Stracke; H Badran; V Semmler; T Reents; S Ammar; S Fichtner; B Haller; G Hessling; I Deisenhofer; C Kolb
Journal:  Clin Res Cardiol       Date:  2012-09-29       Impact factor: 5.460

2.  Life-threatening atrial tachycardia after the Senning operation in a patient with transposition of the great arteries.

Authors:  Shino Chinen; Masaru Miura; Takuya Tamame; Megumi Matsuoka; Hirotaka Ohki; Naokata Sumitomo
Journal:  Heart Vessels       Date:  2011-09-15       Impact factor: 2.037

3.  Retrograde access of the left atrium for pulmonary vein isolation using magnetic navigation after closure of an atrial septum defect.

Authors:  L De Roeck; L Riahi; S Wijchers; D Stockman; Y De Greef; B Schwagten
Journal:  Neth Heart J       Date:  2015-07       Impact factor: 2.380

Review 4.  Advanced ablation strategies for management of post-surgical atrial arrhythmias.

Authors:  Lilian Mantziari; Irina Suman-Horduna; Sonya V Babu-Narayan; Sabine Ernst
Journal:  Glob Cardiol Sci Pract       Date:  2013-11-01

Review 5.  Atrial macroreentry in congenital heart disease.

Authors:  Darragh J Twomey; Prashanthan Sanders; Kurt C Roberts-Thomson
Journal:  Curr Cardiol Rev       Date:  2015
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.