Literature DB >> 18623041

Automated determination of precursor ion, product ion, and neutral loss compositions and deconvolution of composite mass spectra using ion correlation based on exact masses and relative isotopic abundances.

Andrew H Grange1, G Wayne Sovocool.   

Abstract

After an accidental, deliberate, or weather-related dispersion of chemicals (dispersive event), rapid determination of elemental compositions of ions in mass spectra is essential for tentatively identifying compounds. A direct analysis in real time (DART)ion source interfaced to a JEOL AccuTOFmass spectrometer provided exact masses accurate to within 2 mDa for most ions in full scan mass spectra and relative isotopic abundances (RIAs) accurate to within 15-20% for abundant isotopic ions. To speed determination of the correct composition for precursor ions and most product ions and neutral losses, a three-part software suite was developed. Starting with text files of m/z ratios and their ion abundances from mass spectra acquired at low, moderate, and high collision energies, the ion extraction program (IEP) compiled lists for the most abundant monoisotopic ions of their exact masses and the RIAs of the +1 and +2 isotopic peaks when abundance thresholds were met; precursor ions; and higher-mass, precursor-related species. The ion correlation program (ICP) determined if a precursor ion composition could yield a product ion and corresponding neutral loss compositions for each product ion in turn. The input and output program (IOP) provided the ICP with each precursor ion:product ion pair for multiple sets of error limits and prepared correlation lists for single or multiple precursor ions. The software determined the correct precursor ion compositions for 21 individual standards and for three- and seven-component mixtures. Partial deconvolution of composite mass spectra was achieved based on exact masses and RIAs, rather than on chromatography.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18623041     DOI: 10.1002/rcm.3619

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  5 in total

1.  Determination of the presence or absence of sulfur materials in drywall using direct analysis in real time in conjunction with an accurate-mass time-of-flight mass spectrometer.

Authors:  Matthew E Curtis; Patrick R Jones; O David Sparkman; Robert B Cody
Journal:  J Am Soc Mass Spectrom       Date:  2009-07-19       Impact factor: 3.109

2.  Proposed Confidence Scale and ID Score in the Identification of Known-Unknown Compounds Using High Resolution MS Data.

Authors:  Bertrand Rochat
Journal:  J Am Soc Mass Spectrom       Date:  2017-01-23       Impact factor: 3.109

3.  An integrated strategy for comprehensive characterization of metabolites and metabolic profiles of bufadienolides from Venenum Bufonis in rats.

Authors:  Wen-Long Wei; Hao-Jv Li; Wen-Zhi Yang; Hua Qu; Zhen-Wei Li; Chang-Liang Yao; Jin-Jun Hou; Wan-Ying Wu; De-An Guo
Journal:  J Pharm Anal       Date:  2021-02-12

4.  Advances in structure elucidation of small molecules using mass spectrometry.

Authors:  Tobias Kind; Oliver Fiehn
Journal:  Bioanal Rev       Date:  2010-08-21

5.  Assessment of metabolome annotation quality: a method for evaluating the false discovery rate of elemental composition searches.

Authors:  Fumio Matsuda; Yoko Shinbo; Akira Oikawa; Masami Yokota Hirai; Oliver Fiehn; Shigehiko Kanaya; Kazuki Saito
Journal:  PLoS One       Date:  2009-10-16       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.