Fracture behaviour of zirconia ceramic cantilever fixed dental prostheses in vitro.

Olaf Gabbert1, Brigitte Ohlmann, Marc Schmitter, Herbert Gilde, Thomas Ruef, Peter Rammelsberg.   

Abstract

OBJECTIVE: Evaluation of the fracture resistance of all-ceramic cantilever fixed dental prostheses (FDPs) manufactured from zirconia frameworks and veneered with a press ceramic.
MATERIAL AND METHODS: Two mandibular premolars were prepared either with a box inlay cavity or with a full crown chamfer preparation and then duplicated. 40-three-unit cantilever FDPs replacing one premolar, with a group size of eight for each design, were manufactured. In group i-i the cantilever FDPs were retained by two inlays, in group i-c by an inlay-crown combination, and in group c-c by two crowns. The frameworks in groups i-c-R and c-c-R were reinforced by an additional shoulder on the oral side of the zirconia frameworks. All FDPs were subjected to thermal cycling (TC) and 600,000 cycles of mechanical loading (ML) with 50 N. The load to fracture was measured and fracture sites were evaluated.
RESULTS: The mean fracture values ranged from 172 N to 792 N. Fracture-strength values were significantly lower for the i-i retained FDPs than for the i-c and c-c combinations. There was no significant effect of the reinforcing shoulder in groups i-c-R and c-c-R. For FDPs with a crown on the terminal tooth, fractures were usually within the distal wall of the distal crown.
CONCLUSIONS: Inlay-inlay retained cantilever FDPs cannot withstand the mastication forces expected. Fracture load values for inlay-crown and crown-crown-retained FDPs encourage further clinical investigation. The mode of fracture indicates that reinforcement of the distal crown wall might enhance fracture resistance.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18622828     DOI: 10.1080/00016350802241555

Source DB:  PubMed          Journal:  Acta Odontol Scand        ISSN: 0001-6357            Impact factor:   2.331


  2 in total

1.  Impact of simulated reduced alveolar bone support, increased tooth mobility, and distal post-supported, root-treated abutment tooth on load capability of all-ceramic zirconia-supported cantilever FDP.

Authors:  M Naumann; M von Stein-Lausnitz; M Rosentritt; C Walter; H Meyer-Lückel; G Sterzenbach
Journal:  Clin Oral Investig       Date:  2018-02-06       Impact factor: 3.573

2.  All-ceramic prosthetic rehabilitation of a worn dentition: Use of a distal cantilever. Two-year follow-up.

Authors:  Usama N Chekhani; Aikaterini A Mikeli; Fabian K P Huettig
Journal:  Dent Res J (Isfahan)       Date:  2013-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.