In vitro integrity of implant external hexagon after application of surgical placement torque simulating implant locking.

Letícia Resende Davi1, Alexsander Luiz Golin, Sérgio Rocha Bernardes, Cleudmar Amaral de Araújo, Flávio Domingues Neves.   

Abstract

The aim of this study was to evaluate the integrity of the external hexagon of an implant system with internal and external hexagons but with prosthetic connection through the external hexagon (Internal Torque, IT) in comparison with that of an implant system with external hexagon with mount (External Hexagon, EH). A device was made to measure the rotational freedom angles between implant and abutment hexagons in 10 implants from each group after the application of surgical placement torques of 45, 60 and 80 Ncm simulating implant locking. The distances between the vertices of the external hexagon were also obtained. Rotational freedom data were subjected to ANOVA and Tukey's test (P < .05) showing no significant difference between the angles of the intact implants (EH - 3.31 +/- 0.41 degrees and IT - 3.30 +/- 0.17 degrees ) and after application of a 45 Ncm torque (EH - 3.27 +/- 0.38 degrees and IT - 3.31 +/- 0.22 degrees ). However, after application of a 60 Ncm torque there were significant differences (IT - 3.40 +/- 0.20 degrees and EH - 4.03 +/- 0.54 degrees ). After application of a 80 Ncm torque, the IT implant presented values of 3.39 +/- 0.21 degrees whereas the EH did not support the torque, suffering deformation of its external hexagon. Within the limits of this study, it can be concluded that the IT implant system may be preferable in clinical situations where implant placement within a certain bone density could generate torques higher than 60 Ncm.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18622481     DOI: 10.1590/s1806-83242008000200006

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  3 in total

1.  A Finite Element Stress Analysis of a Concical Triangular Connection in Implants: A New Proposal.

Authors:  Romy Angeles Maslucan; John Alexis Dominguez
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

2.  Stability of external and internal implant connections after a fatigue test.

Authors:  Paulo Cesar Pinheiro Feitosa; Ana Paula Barbosa de Lima; Laís Regiane Silva-Concílio; William Cunha Brandt; Ana Christina Claro Neves
Journal:  Eur J Dent       Date:  2013-07

3.  Comparison of fit accuracy and torque maintenance of zirconia and titanium abutments for internal tri-channel and external-hex implant connections.

Authors:  Hakimeh Siadat; Elaheh Beyabanaki; Niloufar Mousavi; Marzieh Alikhasi
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.