Literature DB >> 18621457

Retention of fiber posts cemented at different time intervals in canals obturated using an epoxy resin sealer.

M Vano1, A H Cury, C Goracci, N Chieffi, M Gabriele, F R Tay, M Ferrari.   

Abstract

OBJECTIVES: To evaluate the effect of immediate versus delayed post space preparation and cementation on the retention of different types of fiber posts in canals obturated with an epoxy resin sealer.
METHODS: Sixty-eight single-rooted human teeth were decoronated and the root canals were shaped with rotary instruments and obturated with gutta-percha and an epoxy resin sealer. The teeth were divided into four experimental groups according to the different times of post space preparation and cementation: immediate (group 1), 24h (group 2) and 1 week (group 3) after root canal filling. Control group (group 4) with no root canal obturation was included. Two teeth were randomly selected from each group for SEM examination. Each group was further divided into three subgroups of five teeth each (n=5), according to the type of post and the materials used for luting the posts. A push-out test was performed and differences among experimental groups were analyzed with two-way ANOVA and Tukey test (alpha=0.05).
RESULTS: Interfacial strength values achieved in group 1, where an immediate cementation was performed, were significantly lower (p<0.05) than those in group 2 and group 3 in which post cementation was performed 24h or 1 week after the root canal filling. Post type affected post retention, FRC Postec and DT Light Post posts achieved higher interfacial strengths than ENA Post (p<0.05). SEM examination revealed a more conspicuous presence of sealer remnants on the walls of immediately prepared post spaces.
CONCLUSIONS: Delayed cementation of fiber post resulted in higher retentive strengths irrespective of the post type.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18621457     DOI: 10.1016/j.jdent.2008.05.016

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  3 in total

1.  Effect of different endodontic sealers and time of cementation on push-out bond strength of fiber posts.

Authors:  Danielle Araújo Vilas-Boas; Renata Grazziotin-Soares; Diego Machado Ardenghi; José Bauer; Patrícia Oliveira de Souza; George Táccio de Miranda Candeiro; Etevaldo Matos Maia-Filho; Ceci Nunes Carvalho
Journal:  Clin Oral Investig       Date:  2017-10-11       Impact factor: 3.573

2.  Comparison between immediate and delayed post space preparations: a systematic review and meta-analysis.

Authors:  Alexandre Henrique Dos Reis-Prado; Lucas Guimarães Abreu; Warley Luciano Fonseca Tavares; Isabella Faria da Cunha Peixoto; Ana Cecília Diniz Viana; Elen Marise Castro de Oliveira; Juliana Vilela Bastos; Antônio Paulino Ribeiro-Sobrinho; Francine Benetti
Journal:  Clin Oral Investig       Date:  2021-01-08       Impact factor: 3.573

3.  Effect of calcium silicate-based endodontic sealer on the retention of fiber posts cemented at different time intervals.

Authors:  Sara Abdulrahman Alsubait
Journal:  Saudi Dent J       Date:  2020-04-10
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.