Literature DB >> 18618924

Determination of diazepam and its metabolites in human urine by liquid chromatography/tandem mass spectrometry using a hydrophilic polymer column.

Hironobu Umezawa1, Xiao-Pen Lee, Yoshiko Arima, Chika Hasegawa, Akemi Marumo, Takeshi Kumazawa, Keizo Sato.   

Abstract

Diazepam and its major metabolites, nordazepam, temazepam and oxazepam, in human urine samples, were analyzed by liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using a hydrophilic polymer column (MSpak GF-310 4B), which enables direct injection of crude biological samples. Matrix compounds in urine were eluted first from the column, while the target compounds were retained on the polymer stationary phase. The analytes retained on the column were then eluted into an acetonitrile-rich mobile phase using a gradient separation technique. All compounds showed base-peak ions due to [M+H]+ ions on LC/MS with positive ion electrospray ionization, and product ions were produced from each [M+H]+ ion by LC/MS/MS. Quantification was performed by selected reaction monitoring. All compounds spiked into urine showed method recoveries of 50.1-82.0%. The regression equations for all compounds showed excellent linearity in the range of 0.5-500 ng/mL of urine. The limits of detection and quantification for each compound were 0.1 and 0.5 ng/mL of urine, respectively. The intra- and inter-day coefficients of variation for all compounds in urine were not greater than 9.6%. The data obtained from actual determination of diazepam and its three metabolites, oxazepam, nordazepam and temazepam, in human urine after oral administration of diazepam, are also presented. Copyright (c) 2008 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18618924     DOI: 10.1002/rcm.3613

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  2 in total

1.  Uptake, biotransformation and elimination of selected pharmaceuticals in a freshwater invertebrate measured using liquid chromatography tandem mass spectrometry.

Authors:  Thomas H Miller; Nicolas R Bury; Stewart F Owen; Leon P Barron
Journal:  Chemosphere       Date:  2017-05-13       Impact factor: 7.086

2.  Simultaneous Quantification of Diazepam and Dexamethasone in Plasma by High-Performance Liquid Chromatography with Tandem Mass Spectrometry and Its Application to a Pharmacokinetic Comparison between Normoxic and Hypoxic Rats.

Authors:  Wenwen Gong; Shuhong Liu; Pingxiang Xu; Ming Fan; Ming Xue
Journal:  Molecules       Date:  2015-04-16       Impact factor: 4.411

  2 in total