Literature DB >> 18618476

Surface AFM microscopy of unworn and worn samples of silicone hydrogel contact lenses.

J M González-Méijome1, A López-Alemany, J B Almeida, M A Parafita.   

Abstract

PURPOSE: To evaluate the qualitative and quantitative topographic changes in the surface of worn contact lenses (CLs) of different materials using atomic force microscopy (AFM).
METHODS: The topography of five different CL materials was evaluated with AFM over a surface of 25 microm(2) according to previously published experimental setup. Average roughness (R(a)) and root mean square (Rms) values were obtained for unworn and worn samples.
RESULTS: The R(a) value increased for balafilcon A (11.62-13.68 nm for unworn and worn samples, respectively), lotrafilcon A (3.67-15.01 nm for unworn and worn samples, respectively), lotrafilcon B (4.08-8.42 nm for unworn and worn samples, respectively), galyfilcon A (2.81-14.6 nm for unworn and worn samples, respectively), and comfilcon A (2.87-4.63 nm for unworn and worn samples, respectively). Differences were statistically significant for all lenses except Rms and R(a) for comfilcon A, and R(a) parameter for balafilcon A (p > 0.05). The least relative increase was observed for some balafilcon A samples and for some of these samples the roughness decreased after the lenses had been worn.
CONCLUSION: The changes in surface roughness between unworn and worn lenses are different for different silicone-hydrogel materials. Overall all CLs increased the degree of surface roughness after being worn, even for very short periods of time. However, for samples of balafilcon A, roughness increases at a lower extent or even can decrease as compared to unworn samples of the same material due to filling of the macropores. (c) 2008 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 18618476     DOI: 10.1002/jbm.b.31153

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  3 in total

1.  Atomic force microscopy and Langmuir-Blodgett monolayer technique to assess contact lens deposits and human meibum extracts.

Authors:  Sarah Hagedorn; Elizabeth Drolle; Holly Lorentz; Sruthi Srinivasan; Zoya Leonenko; Lyndon Jones
Journal:  J Optom       Date:  2015-01-22

2.  Atomic force microscopy and scanning electron microscopy analysis of daily disposable limbal ring contact lenses.

Authors:  Kathrine Osborn Lorenz; Joseph Kakkassery; Danielle Boree; David Pinto
Journal:  Clin Exp Optom       Date:  2014-04-02       Impact factor: 2.742

3.  Effect of Three Interventions on Contact Lens Comfort in Symptomatic Wearers: A Randomized Clinical Trial.

Authors:  Maria Navascues-Cornago; Philip B Morgan; Carole Maldonado-Codina
Journal:  PLoS One       Date:  2015-08-12       Impact factor: 3.240

  3 in total