Literature DB >> 18617796

Inspection of lead aprons: a practical rejection model.

W Stam1, M Pillay.   

Abstract

As a sequel to the article by Ken Lambert and Tara McKeon, we propose a model by which defects in lead aprons may easily be evaluated on a routine basis. The model is applicable to lead aprons of various lead equivalent thicknesses. As recommended rejection criteria, we have used the concept of additional dose that an individual might receive due to defects in the lead (Pb) apron. The model has been implemented as an annual quality check in a large medical facility. In this article we consider only dose-related rejection criteria, since financial aspects related to ALARA have already been addressed in the abovementioned article.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18617796     DOI: 10.1097/01.HP.0000314763.19226.86

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  2 in total

1.  Quality Assurance of Personal Radiation Shield for Kilovoltage Photon: A Multicentre Experience.

Authors:  Omemh Bawazeer
Journal:  Risk Manag Healthc Policy       Date:  2021-03-24

2.  A simple quality control tool for assessing integrity of lead equivalent aprons.

Authors:  Roshan S Livingstone; Anna Varghese
Journal:  Indian J Radiol Imaging       Date:  2018 Apr-Jun
  2 in total