Literature DB >> 18617543

Quantitative analysis of anterior segment optical coherence tomography images: the Zhongshan Angle Assessment Program.

J W Console1, L M Sakata, T Aung, D S Friedman, M He.   

Abstract

AIM: To describe a new image analysis method and software for anterior chamber images obtained by the anterior-segment optical coherence tomography (AS-OCT) and to assess its intraobserver and interobserver measurement reproducibility.
METHODS: Twenty 8-bit greyscale 600x300 AS-OCT images with apparent wide angles and 20 images with apparent narrow angles were consecutively selected from a database. Two glaucoma fellowship-trained ophthalmologists used proprietary image analysis software to analyse the images twice. Algorithms defined the borders and curvatures of anterior chamber (AC) structures and measured AC parameters using scleral spur location as the only observer input. The intraobserver and interobserver reproducibility of scleral spur location and angle parameters was calculated in terms of limits of agreement (LOA; mean of differences+/-1.96 SD of differences) and coefficient of variation (CV; SD of differences/overall mean).
RESULTS: The analysis software successfully measured all parameters in all images. When the same image was assessed twice by the same grader, the mean differences ranged from 0 to 0.010 mm in linear measurements and 0.001 to 0.006 mm2 in angle area measurements. LOA tended to be greater in the wider angles. The upper and lower limit values of LOAs were approximately 1/5 to 1/4 of the overall mean. Measurements between two graders had a higher variance. Reproducibility in terms of CV was better in wide angles when compared with narrow angles. The reproducibility of scleral spur placement between observers was poorer in narrow angles (p = 0.001). About 50% of the interobserver variance in angle-area measurements was attributable to the variance of scleral spur placement, while this proportion was only 10-20% in linear measurements.
CONCLUSIONS: Determination of angle parameters using semiautomated software leads to variability in measurement. Variability increases when more than one observer identifies the scleral spur. Variability differs in narrow and open angles, and so including both types is essential when evaluating angle-assessment software. A fully automated analysis and higher image resolution would likely improve quantification of Visante AS-OCT images.

Entities:  

Mesh:

Year:  2008        PMID: 18617543     DOI: 10.1136/bjo.2007.129932

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  38 in total

1.  Differences in baseline dark and the dark-to-light changes in anterior chamber angle parameters in whites and ethnic Chinese.

Authors:  Dandan Wang; Cynthia Chiu; Mingguang He; Lingling Wu; Andrew Kao; Shan Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-12-09       Impact factor: 4.799

2.  Increased lens vault as a risk factor for angle closure: confirmation in a Japanese population.

Authors:  Mineo Ozaki; Monisha E Nongpiur; Tin Aung; Mingguang He; Takanori Mizoguchi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-04-12       Impact factor: 3.117

3.  Ethnic difference of the anterior chamber area and volume and its association with angle width.

Authors:  Dandan Wang; Meng Qi; Mingguang He; Lingling Wu; Shan Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-05-31       Impact factor: 4.799

4.  Ultrasound biomicroscopic evaluation of anterior segment cysts as a risk factor for ocular hypertension and closure angle glaucoma.

Authors:  Abdurrahim Dusak; Mehmet Baykara; Guven Ozkaya; Cuneyt Erdogan; Hikmet Ozcetin; Ercan Tuncel
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

5.  Comparison of factors associated with occludable angle between american Caucasians and ethnic Chinese.

Authors:  Ye Elaine Wang; Yingjie Li; Dandan Wang; Mingguang He; Shan Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-11-21       Impact factor: 4.799

6.  Comparison of phacotrabeculectomy and sequential surgery in the treatment of chronic angle-closure glaucoma coexisted with cataract.

Authors:  Hai-Jun Li; Jie Xuan; Xiao-Min Zhu; Lin Xie
Journal:  Int J Ophthalmol       Date:  2016-05-18       Impact factor: 1.779

7.  Angle-closure glaucoma in Asians: comparison of biometric and anterior segment parameters between Japanese and Chinese subjects.

Authors:  Henrietta Ho; Mineo Ozaki; Takanori Mizoguchi; Shamira A Perera; Daniel H Su; Mingguang He; Tien Y Wong; Monisha E Nongpiur; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-02-01       Impact factor: 3.117

8.  Optimal number of angle images for calculating anterior angle volume and iris volume measurements.

Authors:  Lauren S Blieden; Alice Z Chuang; Laura A Baker; Nicholas P Bell; Timothy S Fuller; Kimberly A Mankiewicz; Robert M Feldman
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-05       Impact factor: 4.799

9.  Deep Learning Classifiers for Automated Detection of Gonioscopic Angle Closure Based on Anterior Segment OCT Images.

Authors:  Benjamin Y Xu; Michael Chiang; Shreyasi Chaudhary; Shraddha Kulkarni; Anmol A Pardeshi; Rohit Varma
Journal:  Am J Ophthalmol       Date:  2019-08-22       Impact factor: 5.258

10.  Association of biometric factors with anterior chamber angle widening and intraocular pressure reduction after uneventful phacoemulsification for cataract.

Authors:  Guofu Huang; Eduardo Gonzalez; Roland Lee; Yi-Chun Chen; Mingguang He; Shan C Lin
Journal:  J Cataract Refract Surg       Date:  2011-11-04       Impact factor: 3.351

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.