Literature DB >> 18617102

Sequential bone healing of immediately loaded mini-implants.

Glaucio Serra1, Liliane S Morais, Carlos Nelson Elias, Marc A Meyers, Leonardo Andrade, Carlos Muller, Marcelo Muller.   

Abstract

INTRODUCTION: The relatively small size and the ability to load mini-implants without delay are important changes in the simplification of bone rigid anchorage. The purpose of this study was to analyze interfacial healing 1, 4, and 12 weeks after the placment of titanium mini-implants in New Zealand rabbits by removal torque test (RTT) and scanning electron microscopy (SEM).
METHODS: Eighteen animals were used in the experiment, in which 72 titanium grade 5 mini-implants 2.0 mm in diameter and 6.0 mm long, were placed. Each animal received 4 mini-implants; 2 were immediately loaded with 1 N.
RESULTS: The RTT means for the unloaded mini-implants at 1, 4, and 12 weeks were 15.2 +/- 4.2 N mm (n = 5), 13.1 +/- 5.7 N mm (n = 5), and 54.4 +/- 12.8 N mm (n = 4), respectively. The loaded groups had means of 12.7 +/- 5.1 N mm (n = 4), 11.1 +/- 5.4 N mm (n = 4), and 32.9 +/- 12.8 N mm (n = 5) for the same healing periods, respectively. The statistical evaluation indicated significance in the comparison between loaded and unloaded 12-week groups (P <0.05). SEM analysis in the loaded group showed the formation of less fibrous interfacial tissue after 4 weeks and more lamellar appearance after 12 weeks.
CONCLUSIONS: The immediate 1-N load did not cause significant changes in the fixation of the mini-implants after 1 and 4 weeks of bone healing. Nevertheless, after 12 weeks, the loaded group had significantly lower RTT values than the unloaded group without compromising the stability of the mini-implants (P <0.05).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18617102     DOI: 10.1016/j.ajodo.2006.09.057

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  5 in total

1.  Comparison between microporous and nanoporous orthodontic miniscrews : An experimental study in rabbits.

Authors:  Yueh-Tse Lee; Eric Jein-Wein Liou; Sinn-Wen Chen
Journal:  J Orofac Orthop       Date:  2022-05-20       Impact factor: 1.938

2.  Nanocrystalline hydroxyapatite for bone repair: an animal study.

Authors:  J Brandt; S Henning; G Michler; W Hein; A Bernstein; M Schulz
Journal:  J Mater Sci Mater Med       Date:  2010-01       Impact factor: 3.896

3.  Biocompatibility of bioabsorbable Mg-Ca alloys with rare earth elements addition.

Authors:  Daniel Fernandes; Celso Resende; Jacqueline Cavalcanti; Dexue Liu; Carlos Elias
Journal:  J Mater Sci Mater Med       Date:  2019-12-03       Impact factor: 3.896

4.  An ectodermal dysplasia patient treated with a small diameter implant supporting a single crown.

Authors:  Andrea Mascolo; Elio Boschetti; Dennis Flanagan
Journal:  Clin Cosmet Investig Dent       Date:  2018-08-10

5.  Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration.

Authors:  Romain Vayron; Vu-Hieu Nguyen; Benoît Lecuelle; Hugues Albini Lomami; Jean-Paul Meningaud; Romain Bosc; Guillaume Haiat
Journal:  Sensors (Basel)       Date:  2018-05-02       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.