Literature DB >> 18607457

Improved accuracy in time-resolved diffuse reflectance spectroscopy.

Erik Alerstam1, Stefan Andersson-Engels, Tomas Svensson.   

Abstract

Significant improvements in the accuracy of time-resolved diffuse reflectance spectroscopy are reached by using a Monte Carlo scheme for evaluation of measured photon time-of-flight distributions. The use of time-resolved diffusion theory of photon migration, being the current standard scheme for data evaluation, is shown defective. In particular, the familiar problem sometimes referred to as absorption-to-scattering coupling or crosstalk, is identified as an error related to the breakdown of the diffusion approximation. These systematic errors are investigated numerically using Monte Carlo simulations, and their influence on data evaluation of experimental recordings are accurately predicted. The proposed Monte Carlo-based data evaluation avoids these errors, and can be used for routine data evaluation. The accuracy and reproducibility of both MC and diffusion modeling are investigated experimentally using the MEDPHOT set of solid tissue-simulating phantoms, and provides convincing arguments that Monte Carlo-based evaluation is crucial in important ranges of optical properties. In contrast to diffusion-based evaluation, the Monte Carlo scheme results in optical properties consistent with phantom design. Since the MEDPHOT phantoms are used for international comparisons and performance assessment, the performed characterization is carefully reported.

Entities:  

Mesh:

Year:  2008        PMID: 18607457     DOI: 10.1364/oe.16.010440

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  6 in total

1.  Study of short-pulse laser propagation in biological tissue by means of the boundary element method.

Authors:  Mohammad Ali Ansari; Reza Massudi
Journal:  Lasers Med Sci       Date:  2011-01-15       Impact factor: 3.161

2.  Evaluation of hyperspectral NIRS for quantitative measurements of tissue oxygen saturation by comparison to time-resolved NIRS.

Authors:  Matthew Kewin; Ajay Rajaram; Daniel Milej; Androu Abdalmalak; Laura Morrison; Mamadou Diop; Keith St Lawrence
Journal:  Biomed Opt Express       Date:  2019-08-23       Impact factor: 3.732

3.  Time-gated perturbation Monte Carlo for whole body functional imaging in small animals.

Authors:  Jin Chen; Xavier Intes
Journal:  Opt Express       Date:  2009-10-26       Impact factor: 3.894

4.  Effect of dependent scattering on the optical properties of Intralipid tissue phantoms.

Authors:  Paola Di Ninni; Fabrizio Martelli; Giovanni Zaccanti
Journal:  Biomed Opt Express       Date:  2011-07-14       Impact factor: 3.732

5.  Smartphone based optical spectrometer for diffusive reflectance spectroscopic measurement of hemoglobin.

Authors:  Perry Edwards; Chenji Zhang; Baigang Zhang; Xiangqian Hong; Vivek K Nagarajan; Bing Yu; Zhiwen Liu
Journal:  Sci Rep       Date:  2017-09-22       Impact factor: 4.379

6.  Spatio-temporal visualization of light transport in complex photonic structures.

Authors:  Lorenzo Pattelli; Romolo Savo; Matteo Burresi; Diederik S Wiersma
Journal:  Light Sci Appl       Date:  2016-05-06       Impact factor: 17.782

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.